Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 1 of 8
1. Product and company identification
Product identifier
Trade name: Pressure Sensitive Tapes
Teflease MG2, MG2R, MG2A, MG2E Yellow, MG2 Orange, Wrightlease 2, 2R,
Wrighlease 4, Toolwright 3, 5, Tooltec A005, A007, A012, Tooltec CS5, CA5, TFG—AH
series
Relevant identified uses of the substance or mixture and uses advised against
General use: Article: Pressure sensitive tape
Details of the supplier of the safety data sheet
Company name:
Airtech International, Inc.
5700 Skylab Road
Huntington Beach, CA 92647
E-mail: airtech@airtechintl.com
Website: www.airtechonline.com
Telephone: +1 714.899.8100
Department responsible for
information:
Telephone: +1 714.899.8100
E-mail: airtech@airtechintl.com
Airtech Europe Sarl
Zone industrielle Haneboesch
L 4562 Differdange
Luxembourg
Website: www.airtech.lu
Telephone: +352 582.282
Department responsible for information:
Telephone: +352 582.282
E-mail: sales@airtech.lu
Tygavac Advanced Materials Ltd.
The Causeway
Broadway Business Park
Chadderton, Oldham
OL9 9XD United Kingdom
Website: www.tygavac.co.uk
Telephone: +44 161.947.1610
Department responsible for
information:
Telephone: +44 161.947.1610
E-mail: sales@tygavac.co.uk
Airtech Asia Ltd.
No. 161 of Anyuan Rd
Chagugang County
Wuqing District
301721, Tianjin, P.R. China
Website: www.airtech.asia
Telephone: +86 22 8862 9800
Telefax:: +86 22 8862 9900
Department responsible for information:
Telephone: +86 22 8862 9800
E-mail: airtech.asia@airtechasia.com.cn
Emergency phone number
CHEMTREC EMERGENCY PHONE:
Within USA/Canada: 1-(800)424-9300
International: +1 703-741-5970
2. Hazards identification
Emergency overview
Appearance: Form: solid
Color: varying
Odor: odorless
Classification: Article not subject to hazard labelling or classification.
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 2 of 8
Regulatory status
This material is not considered hazardous by the U.S. OSHA Hazard Communication
Standard (29 CFR 1910.1200) and WHMIS in Canada.
Hazards not otherwise classified
Toxic fumes may be emitted at elevated temperatures. Do not breathe vapor. Inhalation of
fumes from burning or heating may cause polymer fume fever, a temporary flu-like illness
with fever and chills. Processing, e.g. by cutting, sawing or grinding, can produce
particles and dust. Avoid inhalation of dusts, as even inert dusts may functionally affect
respiratory organs.
see section 11: Toxicological information
3. Composition / Information on ingredients
Chemical characterization:Article: Pressure sensitive tape
Carrier type: PTFE, PTFE/Glass, cloth, fluoropolymer
Adhesive type: Silicone, rubber or acrylic
4. First aid measures
In case of inhalation:In case of inhalation of decomposition products, affected person should be moved into
fresh air and kept still. If the casualty has difficulty breathing, call a doctor immediately.
Following skin contact:Thoroughly wash skin with soap and water. In case of skin irritation, consult a physician.
After eye contact: In the event of irritation from processing vapors: Immediately flush eyes with plenty of
flowing water for 10 to 15 minutes holding eyelids apart. In case of troubles or persistent
symptoms, consult an opthalmologist.
After swallowing: Not a probable route of exposure.
Most important symptoms/effects, acute and delayed
In case of inhalation:
Overheating released mist or vapors can irritate the respiratory tracts. Inhalation of fumes
from burning or heating may cause polymer fume fever, a temporary flu-like illness with
fever and chills.
The following symptoms may occur: Irritation of nose, throat, lung cough, discomfort,
shortage of breath, headache, dizziness, nausea, vomiting. Symptoms usually appear
after 2 hours and decline within the next 36 to 48 hours. In case of prolonged exposure:
Possible danger of damage to liver and kidneys.
After contact with skin: Itching redness of the skin
The melted product can cause severe burns.
After eye contact: Process vapors can irritate the eyes.
Information to physician
Treat symptomatically.
5. Fire fighting measures
Flash point/flash point range:
No data available
Auto-ignition temperature:No data available
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 3 of 8
Suitable extinguishing media:
Water spray jet, dry chemical powder, foam, carbon dioxide
Extinguishing media which must not be used for safety reasons:
Full water jet.
Specific hazards arising from the chemical
Toxic fumes may be emitted at elevated temperatures. (> 380 C)
In case of strong heating / In case of fire may be liberated: Hydrogen fluoride, Carbonyl
difluoride, Tetrafluoroethylene, Hexafluoropropylene, Perfluoroisobutylene, carbon
monoxide and carbon dioxide.
Protective equipment and precautions for firefighters:
Wear a self-contained breathing apparatus and chemical protective clothing.
Additional information:Seal off endangered area. Cool endangered containers with water spray and, if possible,
remove from danger zone. Use a water fog to control vapors. Do not breathe fumes. Do
not allow fire water to penetrate into surface or ground water.
6. Accidental release measures
Personal precautions:Handle in accordance with good industrial hygiene and safety practice.
At processing: Avoid the formation of aerosol/vapors. Avoid inhalation and contact with
skin and eyes. Wear appropriate protective equipment. Keep unprotected people away.
Ensure adequate ventilation, especially in confined areas.
Environmental precautions:
Do not allow to penetrate into soil, waterbodies or drains.
Methods for clean-up:Take up mechanically, placing in appropriate containers for disposal. Dispose of waste
according to applicable legislation.
7. Handling and storage
Handling
Advices on safe handling:Handle in accordance with good industrial hygiene and safety practice.
At processing: Provide adequate ventilation, and local exhaust as needed. Avoid the
formation of aerosol/vapors. Avoid inhalation and contact with skin and eyes. Wear
appropriate protective equipment. Keep unprotected people away. When using do not eat,
drink or smoke.
Precautions against fire and explosion:
Take standard precautions to prevent fire.
Storage
Requirements for storerooms and containers:
Keep in a cool place. Keep container dry. Protect from direct sunlight. Store at room
temperature.
Hints on joint storage:Incompatible materials: Strong bases, strong acids, strong oxidizing agents.
Keep away from food and drinks.
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 4 of 8
8. Exposure controls / personal protection
Exposure guidelines
Occupational exposure limit values:
Type Limit value
USA: ACGIH: TWA 10 mg/m (Dust limit value, inhalable fraction)
USA: ACGIH: TWA 3 mg/m (Dust limit value, respirable fraction)
USA: OSHA: TWA 15 mg/m (Dust limit value, inhalable fraction)
USA: OSHA: TWA 5 mg/m (Dust limit value, respirable fraction)
Engineering controls
Provide good ventilation and/or an exhaust system in the work area.
In case of development of vapors or dust (at processing): Use local exhaust.
See also information in chapter 7, section storage.
Personal protection equipment (PPE)
Eye/face protection:At processing (recommended): Safety glasses in accordance with OSHA 29 CFR:
1910.133 or ANSI Z87.1-2010.
Skin protection: At processing (recommended): Wear suitable protective clothing.
Recommendation:
Protective gloves according to OSHA Standard – 29 CFR: 1910.138.
Glove material: nitrile rubber (0.11 mm)
Breakthrough time: 480 min.
Observe glove manufacturer’s instructions concerning penetrability and breakthrough time.
Respiratory protection:Respiratory protection is not necessary if room is well ventilated.
At processing:
When vapors form, use respiratory protection. The filter class must be suitable for the
maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise
when handling the product. If the concentration is exceeded, self-contained breathing
apparatus must be used.
General hygiene considerations:
Handle in accordance with good industrial hygiene and safety practice. Wash hands
before breaks and after work. When using do not eat, drink or smoke.
At processing:
Avoid contact with skin, eyes, and clothing. Do not breathe vapors. Do not breathe dust.
9. Physical and chemical properties
Information on basic physical and chemical properties
Appearance: Form: solid
Color: varying
Odor: odorless
Odor threshold: No data available
pH value: No data available
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 5 of 8
Melting point/freezing point: No data available
Initial boiling point and boiling range:No data available
Flash point/flash point range: No data available
Evaporation rate: No data available
Flammability: This material is combustible, but will not ignite readily.
Explosion limits: No data available
Vapor pressure: No data available
Vapor density: No data available
Density: No data available
Water solubility: insoluble
Partition coefficient: n-octanol/water:No data available
Auto-ignition temperature: No data available
Thermal decomposition: No data available
Additional information: No data available
10. Stability and reactivity
Reactivity: Refer to section: Possibility of hazardous reactions.
Chemical stability:Stable under recommended storage conditions.
Possibility of hazardous reactions:
No dangerous reactions with proper and specified storage and handling
Conditions to avoid:Keep away from heat. Protect from direct sunlight. Avoid generation of dust. Avoid the
formation of aerosol/vapors.
Incompatible materials:Strong bases, strong acids, strong oxidizing agents.
Hazardous decomposition products:
In case of strong heating / In case of fire may be liberated: Hydrogen fluoride, Carbonyl
difluoride, Tetrafluoroethylene, Hexafluoropropylene, Perfluoroisobutylene, carbon
monoxide and carbon dioxide.
Thermal decomposition:No data available
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 6 of 8
11. Toxicological information
Toxicological tests
Toxicological effects:Acute toxicity (oral): Lack of data.
Acute toxicity (dermal): Lack of data.
Acute toxicity (inhalative): Lack of data.
Skin corrosion/irritation: Lack of data.
Serious eye damage/irritation: Lack of data.
Sensitisation to the respiratory tract: Lack of data.
Skin sensitisation: Lack of data.
Germ cell mutagenicity/Genotoxicity: Lack of data.
Carcinogenicity: Lack of data.
Reproductive toxicity: Lack of data.
Effects on or via lactation: Lack of data.
Specific target organ toxicity (single exposure): Lack of data.
Specific target organ toxicity (repeated exposure): Lack of data.
Aspiration hazard: Lack of data.
Other information: Toxic fumes may be emitted at elevated temperatures.
Hazardous decomposition products:
Hydrogen fluoride, Hexafluoropropene, Carbonyl difluoride,
Symptoms
In case of inhalation:
Overheating released mist or vapors can irritate the respiratory tracts. Inhalation of fumes
from burning or heating may cause polymer fume fever, a temporary flu-like illness with
fever and chills.
The following symptoms may occur: Irritation of nose, throat, lung cough, discomfort,
shortage of breath, headache, dizziness, nausea, vomiting. Symptoms usually appear
after 2 hours and decline within the next 36 to 48 hours. In case of prolonged exposure:
Possible danger of damage to liver and kidneys.
After contact with skin: Itching redness of the skin
The melted product can cause severe burns.
After eye contact: Process vapors can irritate the eyes.
12. Ecological information
Ecotoxicity
Effects in sewage plants:The insoluble part can be precipitated mechanically in suitable sewage treatment plants.
Further details: No data available
Mobility in soil
No data available
Persistence and degradability
Further details: Product is not biodegradable.
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 7 of 8
Additional ecological information
General information:Do not allow to penetrate into soil, waterbodies or drains.
13. Disposal considerations
Product
Recommendation: Dispose of waste according to applicable legislation.
Contaminated packaging
Recommendation: Dispose of waste according to applicable legislation. Handle contaminated packages in
the same way as the substance itself. Non-contaminated packages may be recycled. Do
not remove label until container is thoroughly cleaned.
14. Transport information
USA: Department of Transportation (DOT)
Proper shipping name: Not restricted
Sea transport (IMDG)
Proper shipping name: Not restricted
Marine pollutant: no
Air transport (IATA)
Proper shipping name: Not restricted
Further information
No dangerous good in sense of these transport regulations.
15. Regulatory information
National regulations – U.S. Federal Regulations
This product is an article as defined by TSCA regulations, and is exempt from TSCA
inventory listing requirements.
National regulations – Great Britain
Hazchem-Code: –
16. Other information
Hazard rating systems:
1
10
NFPA Hazard Rating:
Health: 1 (Slight)
Fire: 1 (Slight)
Reactivity: 0 (Minimal)
HEALTH 1
FLAMMABILITY 1
PHYSICAL HAZARD 0
X
HMIS Version III Rating:
Health: 1 (Slight)
Flammability: 1 (Slight)
Physical Hazard: 0 (Minimal)
Personal Protection: X = Consult your supervisor
printed by Airtech Advanced Materials Group with Qualisys SUMDAT

Safety information sheet
Voluntary product information following the Safety Data Sheet format
Pressure Sensitive Tapes
Material number 1092
Revision date: 9/13/2019
Version: 5
Language: en-US
Date of first version:7/27/2015
Page: 8 of 8
Reason of change: Changes in section 1: Changes of product list Changes in section 1:
Company/undertaking identification
Department issuing data sheet
Contact person: see section 1: Department responsible for information
This data sheet cannot cover all possible situations which the user may experience during processing. Each
aspect of your operation should be examined to determine if, and which additional precautions may be
necessary. All health and safety information contained in this data sheet should be provided to your
employees and customers. It is your responsibility to develop appropriate workplace instructions and training
programs for employees.
As the conditions and methods of use are beyond our control, we do not assume any responsibility and
expressly disclaim any liability for any use of this product. The information supplied on this safety data sheet
complies with our current level of knowledge as well as with national and EU regulations. All statements or
suggestions are made without warranty, expressed or implied, regarding accuracy of information, the hazards
connected with the use of the product or the results to be obtained from the use thereof.
printed by Airtech Advanced Materials Group with Qualisys SUMDAT