MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 1of 9
Material Safety Data Sheet
Copyright, 2010, 3M Company. All rights reserved. Copying and/or downloading of this information for the purpose of properly
utilizing 3M products is allowed provided that: (1) the information is copied in full with no changes unless prior written agreement is
obtained from 3M, and (2) neither the copy nor the original is resold or otherwise distributed with the intention of earning a profit
thereon.
SECTION 1: PRODUCT AND COMPANY IDENTIFICATION
PRODUCT NAME: 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805
MANUFACTURER: 3M
DIVISION: Automotive Aftermarket
ADDRESS: 3M Center
St. Paul, MN 55144-1000
EMERGENCY PHONE: 1-800-364-3577 or (651) 737-6501 (24 hours)
Issue Date: 04/14/10
Supercedes Date: 11/10/08
Document Group:24-7586-1
Product Use:
Intended Use: Automotive
SECTION 2: INGREDIENTS
Ingredient C.A.S. No. % by Wt
PROPRIETARY RESIN Trade Secret 15 -40
TALC 14807-96-6 10 -30
LIMESTONE 1317-65-3 10 -30
STYRENE MONOMER 100-42-5 10 -30
MAGNESIUM CARBONATE 546-93-0 5 -10
SODIUM SILICATE 1344-09-8 3 -7
SYNTHETIC CRYSTALLINE -FREE SILICA GEL 112926-00-8 1 -5
QUARTZ SILICA 14808-60-7 < 0.5
SECTION 3: HAZARDS IDENTIFICATION
3.1 EMERGENCY OVERVIEW
Odor, Color, Grade: Strong Solvent -Pungent Odor Gray Paste
General Physical Form: Liquid
Immediate health, physical, and environmental hazards: Flammable liquid and vapor. Closed containers exposed to heat from
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 2of 9
fire may build pressure and explode. Vapors may travel long distances along the ground or floor to an ignition source and flash back.
Maycause target organ effects. Contains a chemical or chemicals which can cause cancer.
3.2 POTENTIAL HEALTH EFFECTS
Eye Contact:
Moderate Eye Irritation: Signs/symptoms may include redness, swelling, pain, tearing, and blurred or hazy vision.
Skin Contact:
Moderate Skin Irritation: Signs/symptoms may include localized redness, swelling, itching, and dryness.
Inhalation:
RespiratoryTract Irritation: Signs/symptoms may include cough, sneezing, nasal discharge, headache, hoarseness, and nose and
throat pain.
Prolonged or repeated exposure may cause:
Pneumoconiosis: Sign/symptoms may include persistent cough, breathlessness, chest pain, increased amounts of sputum, and
changes in lung function tests.
Maybe absorbed following inhalation and cause target organ effects.
Ingestion:
Gastrointestinal Irritation: Signs/symptoms may include abdominal pain, stomach upset, nausea, vomiting and diarrhea.
Maybe absorbed following ingestion and cause target organ effects.
Target Organ Effects:
Central Nervous System (CNS) Depression: Signs/symptoms may include headache, dizziness, drowsiness, incoordination, nausea,
slowed reaction time, slurred speech, giddiness, and unconsciousness.
Liver Effects: Signs/symptoms may include loss of appetite, weight loss, fatigue, weakness, abdominal tenderness and jaundice.
AuditoryEffects: Signs/symptoms may include hearing impairment, balance dysfunction and ringing in the ears.
Prolonged or repeated exposure may cause:
Neurological Effects: Signs/symptoms may include personality changes, lack of coordination, sensory loss, tingling or
numbness of the extremities, weakness, tremors, and/or changes in blood pressure and heart rate.
Ocular Effects: Signs/symptoms may include blurred or significantly impaired vision.
Kidney/Bladder Effects: Signs/symptoms may include changes in urine production, abdominal or lower back pain, increased
protein in urine, increased blood urea nitrogen (BUN), blood in urine, and painful urination.
Immunological Effects: Signs/symptoms may include alterations in the number of circulating immune cells, allergic skin and
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 3of 9
/or respiratoryreaction, and changes in immune function.
Carcinogenicity:
Contains a chemical or chemicals which can cause cancer.
IngredientC.A.S. No. Class Description Regulation
QUARTZ SILICA 14808-60-7 Grp. 1: Carcinogenic to
humans
International Agency for Research on Cancer
QUARTZ SILICA 14808-60-7 Known human carcinogen National Toxicology Program Carcinogens
STYRENE MONOMER 100-42-5 Grp. 2B: Possible human carc.International Agency for Research on Cancer
SECTION 4: FIRST AID MEASURES
4.1 FIRST AID PROCEDURES
The following first aid recommendations are based on an assumption that appropriate personal and industrial hygiene practices are
followed.
Eye Contact: Flush eyes with large amounts of water. If signs/symptoms persist, get medical attention.
Skin Contact: Remove contaminated clothing and shoes. Immediately flush skin with large amounts of water. Get medical
attention. Wash contaminated clothing and clean shoes before reuse.
Inhalation: Remove person to fresh air. If signs/symptoms develop, get medical attention.
If Swallowed: Do not induce vomiting unless instructed to do so by medical personnel. Give victim two glasses of water. Never
give anything by mouth to an unconscious person. Get medical attention.
SECTION 5: FIRE FIGHTING MEASURES
5.1 FLAMMABLE PROPERTIES
Autoignition temperature No Data Available
Flash Point 88 F [Test Method: Closed Cup]
Flammable Limits -LEL No Data Available
Flammable Limits -UEL No Data Available
OSHA Flammability Classification: Class IC Flammable Liquid
5.2 EXTINGUISHING MEDIA
Use fire extinguishers with class B extinguishing agents (e.g., dry chemical, carbon dioxide).
5.3 PROTECTION OF FIRE FIGHTERS
Special Fire Fighting Procedures: Water may not effectively extinguish fire; however, it should be used to keep fire-exposed
containers and surfaces cool and prevent explosive rupture. Wear full protective equipment (Bunker Gear) and a self-contained
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 4of 9
breathing apparatus (SCBA).
Unusual Fire and Explosion Hazards: Flammable liquid and vapor. Closed containers exposed to heat from fire may build
pressure and explode. Vapors may travel long distances along the ground or floor to an ignition source and flash back.
Note: See STABILITY AND REACTIVITY (SECTION 10) for hazardous combustion and thermal decomposition
information.
SECTION 6: ACCIDENTAL RELEASE MEASURES
Accidental Release Measures:
For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapors, in accordance with good
industrial hygiene practice. Warning! A motor could be an ignition source and could cause flammable gases or vapors in the spill area
to burn or explode. Remember, adding an absorbent material does not remove a toxic, corrosivity or flammability hazard.
Place in a metal container approved for transportation by appropriate authorities.
Refer to other sections of this MSDS for information regarding physical and health hazards, respiratory protection, ventilation, and
personal protective equipment. Call 3M-HELPS line (1-800-364-3577) for more information on handling and managing the spill.
Cover spill area with a fire-extinguishing foam designed for use on solvents, such as alcohols and acetone, that can dissolve in water.
An AR -AFFF type foam is recommended. Clean up residue with an appropriate solvent selected by a qualified and authorized
person. Ventilate the area with fresh air. Read and follow safety precautions on the solvent label and MSDS. Seal the container.
In the event of a release of this material, the user should determine if the release qualifies as reportable according to
local, state, and federal regulations.
SECTION 7: HANDLING AND STORAGE
7.1 HANDLING
Keep away from heat, sparks, open flame, pilot lights and other sources of ignition. Ground containers securely when transferring
contents. Wear low static or properly grounded shoes. Avoid breathing of vapors, mists or spray. Avoid static discharge. Avoid eye
contact with vapors, mists, or spray. Keep container closed when not in use. Avoid breathing of dust created by cutting, sanding,
grinding or machining. Avoid contact with oxidizing agents.
7.2 STORAGE
Store away from acids. Store away from heat. Store out of direct sunlight. Keep container tightly closed. Store away from oxidizing
agents.
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
8.1 ENGINEERING CONTROLS
Provide appropriate local exhaust for cutting, grinding, sanding ormachining. Use general dilution ventilation and/or local exhaust
ventilation to control airborne exposures to below Occupational Exposure Limits and/or control mist, vapor, or spray. If ventilation is
not adequate, use respiratory protection equipment.
8.2 PERSONAL PROTECTIVE EQUIPMENT (PPE)
8.2.1 Eye/Face Protection
Avoid eye contact with vapors, mists, or spray.
The following eye protection(s) are recommended: Safety Glasses with side shields
.
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 5of 9
8.2.2 Skin Protection
Avoid skin contact. Avoid prolonged or repeated skin contact.
Select and use gloves and/or protective clothing to prevent skin contact based on the results of an exposure assessment. Consult with
your glove and/or protective clothing manufacturer for selection of appropriate compatible materials.
Gloves made from the following material(s) are recommended: Nitrile Rubber
.
8.2.3 Respiratory Protection
Avoid breathing of vapors, mists or spray. Avoid breathing of dust created by cutting, sanding, grinding or machining.
Select one of the following NIOSH approved respirators based on airborne concentration of contaminants and in accordance with
OSHA regulations: Half facepiece or fullface air-purifying respirator with P100 particulate filters
. Consult the current 3M Respiratory Selection Guide for additional information or call 1-800-243-4630 for 3M technical assistance.
8.2.4 Prevention of Swallowing
Do not eat, drink or smoke when using this product. Wash exposed areas thoroughly with soap and water. Do not ingest.
8.3 EXPOSURE GUIDELINES
IngredientAuthorityType Limit Additional Information
LIMESTONE OSHA TWA, respirable
fraction
5 mg/m3
LIMESTONE OSHA TWA, as total dust15 mg/m3
MAGNESIUM CARBONATE OSHA TWA, respirable
fraction
5 mg/m3
MAGNESIUM CARBONATE OSHA TWA, as total dust15 mg/m3
QUARTZ SILICA ACGIH TWA, respirable
fraction
0.025 mg/m3
QUARTZ SILICA OSHA TWA concentration,
respirable
0.1 mg/m3
QUARTZ SILICA OSHA TWA concentration,
as total dust
0.3 mg/m3
STYRENE MONOMER ACGIH TWA 20 ppm
STYRENE MONOMER ACGIH STEL 40 ppm
STYRENE MONOMER OSHA TWA 100 ppm
STYRENE MONOMER OSHA CEIL 200 ppm
TALC ACGIH TWA, respirable
fraction
2 mg/m3
TALC CMRG TWA, as respirable
dust
0.5 mg/m3
TALC OSHA TWA concentration,
respirable
0.1 mg/m3
TALC OSHA TWA concentration,
as total dust
0.3 mg/m3
TALC OSHA TWA 20 millions of
particles/cu. ft.
SOURCE OF EXPOSURE LIMIT DATA:
ACGIH: American Conference of Governmental Industrial Hygienists
CMRG: Chemical Manufacturer Recommended Guideline
OSHA: Occupational Safety and Health Administration
AIHA: American Industrial Hygiene Association Workplace Environmental Exposure Level (WEEL)
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 6of 9
Odor, Color, Grade: Strong Solvent -Pungent Odor Gray Paste
General Physical Form: Liquid
Autoignition temperature No Data Available
Flash Point 88 F [Test Method: Closed Cup]
Flammable Limits -LEL No Data Available
Flammable Limits -UEL No Data Available
Boiling point 293 F
Density 1.134 g/ml
Vapor Density 3.6 g/cm3
Vapor Density No Data Available
Vapor Pressure No Data Available
Vapor Pressure No Data Available
Specific Gravity 2.75 g/cm3
pH No Data Available
Melting point No Data Available
Solubility In Water No Data Available
Solubility in Water No Data Available
Evaporation rate No Data Available
Volatile Organic Compounds 16.52 % [Test Method: calculated SCAQM rule 443.1]
Kow -Oct/Water partition coef No Data Available
Percent volatile 16.52 %
VOC Less H2O & Exempt Solvents 459.39 g/l
Viscosity 192000 -208000 centipoise
Conditions to avoid Sparks and/or flames
Conditions to avoid Heat
SECTION 10: STABILITY AND REACTIVITY
Stability:Stable.
Materials and Conditions to Avoid:
10.1 Conditions to avoid
Sparks and/or flames
Heat
10.2 Materials to avoid
Strong acids
Strong oxidizing agents
Hazardous Polymerization: Hazardous polymerization will not occur.
Hazardous Decomposition or By-Products
Substance Condition
Carbon monoxide During Combustion
Carbon dioxide During Combustion
SECTION 11: TOXICOLOGICAL INFORMATION
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 7of 9
Please contact the address listed on the first page of the MSDS for Toxicological Information on this material and/or its
components.
SECTION 12: ECOLOGICAL INFORMATION
ECOTOXICOLOGICAL INFORMATION
Not determined.
CHEMICAL FATE INFORMATION
Not determined.
SECTION 13: DISPOSAL CONSIDERATIONS
Waste Disposal Method: Incinerate in a permitted hazardous waste incinerator. As a disposal alternative, dispose of waste product
in a permitted hazardous waste facility.
EPA Hazardous Waste Number (RCRA):D001 (Ignitable)
Since regulations vary, consult applicable regulations or authorities before disposal.
SECTION 14:TRANSPORT INFORMATION
LB-K100-0519-5, LB-K100-0519-6, LB-K100-0519-7, LB-K100-0519-8, LB-K100-0585-9
Please contact the emergency numbers listed on the first page of the MSDS for Transportation Information for this
material.
SECTION 15: REGULATORY INFORMATION
US FEDERAL REGULATIONS
Contact 3M for more information.
311/312 Hazard Categories:
Fire Hazard -Yes Pressure Hazard -No Reactivity Hazard -No Immediate Hazard -Yes Delayed Hazard -Yes
Section 313 Toxic Chemicals subject to the reporting requirements of that section and 40 CFR part 372 (EPCRA):
Ingredient C.A.S. No% by Wt
STYRENE MONOMER 100-42-5 10 -30
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 8of 9
STATE REGULATIONS
Contact 3M for more information.
CALIFORNIA PROPOSITION 65
IngredientC.A.S. No. Classification
SILICA, CRYSTALLINE (AIRBORNE
PARTICLES OF RESPIRABLE SIZE)
SEQ677 **Carcinogen
** WARNING: contains a chemical which can cause cancer.
CHEMICAL INVENTORIES
The components of this product are in compliance with the chemical notification requirements of TSCA.
All applicable chemical ingredients in this material are listed on the European Inventory of Existing Chemical Substances (EINECS),
orare exempt polymers whose monomers are listed on EINECS.
Contact 3M for more information.
INTERNATIONAL REGULATIONS
Contact 3M for more information.
This MSDS has been prepared to meet the U.S. OSHA Hazard Communication Standard, 29 CFR 1910.1200.
SECTION 16: OTHER INFORMATION
NFPA Hazard Classification
Health: 2 Flammability: 3 Reactivity: 0 Special Hazards: None
National Fire Protection Association (NFPA) hazard ratings are designed for use by emergency response personnel to address the hazards that are
presented by short-term, acute exposure to a material under conditions of fire, spill, or similar emergencies. Hazard ratings are primarily based on the
inherent physical and toxic properties of the material but also include the toxic properties of combustion or decomposition products that are known to
be generated in significant quantities.
Revision Changes:
Section 1: Product name was modified.
Copyright was modified.
Section 8: Eye/face protection information was modified.
Section 8: Skin protection -recommended gloves information was modified.
MATERIAL SAFETY DATA SHEET 3M 3M Lightweight Body Filler 5800, 5801, 5804, 5805 04/14/10
_________________________________________________________________________________________________
Page 9of 9
Section 8: Respiratory protection -recommended respirators information was modified.
Page Heading: Product name was modified.
Section 9: Property description for optional properties was modified.
Section 8: Exposure guidelines ingredient information was modified.
Section 3: Carcinogenicity table was modified.
Section 15: California proposition 65 ingredient information was modified.
Section 5: OSHA flammability heading was added.
Section 5: OSHA flammability data was added.
Section 9: Property description forrequired properties was added.
Section 10.1 Conditions to avoid heading was added.
Section 10.2 Materials to avoid heading was added.
Section 6: Personal precautions information was added.
Section 6: Environmental procedures information was added.
Section 6: Methods for cleaning up information was added.
Section 10: Materials to avoid physical property was added.
Section 10: Conditions to avoid physical property was added.
Section 6: Release measures information was deleted.
Section 10: Materials and conditions to avoid physical property was deleted.
Section 8: Exposure guidelines legend was deleted.
Section 8: Exposure guideline note was deleted.
DISCLAIMER: The information in this Material Safety Data Sheet (MSDS) is believed to be correct as of the date issued. 3M
MAKES NO WARRANTIES, EXPRESSE OR IMPLIED, INCLUDING, BUT NOT LIMITE TO, ANY IMPLIE WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFORMANCE OR USAGE OF
TRADE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user's method of
use or application. Given the variety of factors that can affect the use and application of a 3M product, some of which are uniquely
within the user's knowledge and control, it is essential that the user evaluate the 3M product to determine whether it is fit for a
particular purpose and suitable for user's method of use or application.
3M provides information in electronic form as a service to its customers. Due to the remote possibility that electronic transfer may
have resulted in errors, omissions or alterations in this information, 3M makes no representations as to its completeness or accuracy.
In addition, information obtained from a database may not be as current as the information in the MSDS available directly from 3M.
3M MSDSs are available at www.3M.com