Accella Polyurethane Systems
Safety Data Sheet
1.Identification of Substance:
Product Name: 3001 Series B
Supplier Identification:
Accella Polyurethane Systems
Address:
8530 Milliken Ave. Adie
Rancho Cucamonga, CA 91730
Telephone:
(909) 941-4999
24-Hr. Emergency Phone Number:
CHEMTREC (800) 424-9300
Product Use: Polyurethane polyol component
2.Hazards Identification:
GHS Ratings:
Skin sensitizer 1 Skin sensitizer
GHS Hazards
H317 May cause an allergic skin reaction
GHS Precautions
P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P272 Contaminated work clothing should not be allowed out of the workplace
P280 Wear protective gloves/protective clothing/eye protection/face protection
P321 Specific treatment is urgent (see Section 4 First Aid measures)
P363 Wash contaminated clothing before reuse
P302+P352 IF ON SKIN: Wash with soap and water
P333+P313 If skin irritation or a rash occurs: Get medical advice/attention
P501 Dispose of contents/container in accordance with existing federal, state, and local
environmental control laws.
Signal Word: Warning
Acute Toxicity:
Eyes: Liquid may cause irritation.
Skin: Minor potential for irritation.
Inhalation: Liquid may cause irritation.
Ingestion: Consult physician.
Chronic Effects: Not expected to cause any adverse chronic health effects.
SDS for: 3001 Series B
Page 1 of 5
Printed: 9/20/2017 at 1:20:13PM

3. Composition/Data on Components:

Chemical Name CAS number Weight Concentration %
1,4-Diazabicyclo[2.2.2]octane 280-57-9 0.10% – 1.00%
4. First Aid Measures:

Inhalation: Move to fresh air. If breathing is difficult, give oxygen.

After Eye Contact: Rinse opened eye for at least 15 minutes under running water.
Remove contact lenses if present and easy to do so, and continue rinsing.

After Skin Contact: Clean affected area with soap and plenty of water.

After Swallowing: Consult physician.

Notes to Physician: Treat symptomatically
5. Fire Fighting Measures:
Flash Point: 200 C (392 F)
LEL: N/A UEL: N/A
Flammable limits listed if known
Suitable Extinguishing Agents: Water spray, CO2, Foam, Dry chemical

Information about Protection against Explosions and Fires: Closed containers may
rupture when exposed to extreme heat.

Dangerous Products of Decomposition: Oxides of carbon, hydrocarbons.

Protective Equipment: Firefighters should wear a pressure demand self-contained breathing apparatus and protective
clothing.
6. Accidental Release Measures:

Person-Related Safety Precautions: Avoid contact with skin and eyes.

Measures for Environmental Protection: Cover and contain spill with absorbent material. Collect for proper disposal
according to local, state, and federal regulations.

7. Handling and Storage:

SDS for: 3001 Series B
Page 2 of 5
Printed: 9/20/2017 at 1:20:13PM

Information for Safe Handling: Avoid contact with skin or inhalation.
Storage Requirements: Store in dry, well ventilated area. Keep containers tightly closed. Store between 60 F-100 F.
Material may settle.
8.Exposure Controls and Personal Protection:
Other Exposure Limits ACGIH Exposure Limits OSHA Exposure Limits Chemical Name / CAS No.
1,4-Diazabicyclo[2.2.2]octane
280-57-9
Not Established Not Established Not Established
Engineering Controls: No specific measures required.
General Protective and Hygienic Measures: Usual precautionary measures should be adhered to when handling
chemicals.
Respiratory Protection: None required if work area is properly ventilated.
Protection of Hands: Protective chemical resistant gloves.
Eye Protection: Safety glasses.
Body Protection: Protective work clothing. Launder separately.
9.Physical and Chemical Properties:
Physical properties listed where known.
Mild Odor: Appearance: Clear s
traw color liquid
Vapor Pressure: N/A
N/A Odor threshold:
N/A pH:
N/A Melting point:
N/A Solubility:
392 F,200 C Flash point:
N/A Flammability:
Vapor Density: N/A
Specific Gravity 1.05
Freezing point: N/A
Boiling range: 100 C
Evaporation rate: N/A
Explosive Limits: N/A N/A Partition coefficient
(n-octanol/water):
N/A Autoignition temperature: N/A Decomposition temperature:
10.Stability and Reactivity:
Incompatible Materials: Avoid contact with isocyanates and strong oxidizing agents.
Hazardous Polymerization: Not expected to occur.
Dangerous Products of Decomposition: Oxides of carbon, hydrocarbons.
11.Toxicological Information:
Mixture Toxicity
Component Toxicity
280-57-9 1,4-Diazabicyclo[2.2.2]octane
Oral LD50: 1,700 mg/kg (Rat) Dermal LD50: 3,200 mg/kg (Rabbit)
SDS for: 3001 Series B
Page 3 of 5
Printed: 9/20/2017 at 1:20:13PM

Toxicity Values Listed if Known
Acute Toxicity:
Eyes: Liquid may cause irritation.
Skin: Minor potential for irritation.
Inhalation: Liquid may cause irritation.
Ingestion: Consult physician.
Chronic Effects: May cause skin sensitization.
Routes of Entry : Ingestion, inhalation, skin contact.
Target Organs: Skin.
Chemicals with Known or Possible Carcinogenic Effects:
Carcinogen Rating CAS Number Description % Weight
None None
12. Ecological Information:
General Information: Based on experience, no adverse effects are to be expected if correct disposal procedures have
been followed as indicated in section 13. Individual component ecotoxicity listed if known.
Component Ecotoxicity
1,4-Diazabicyclo[2.2.2]octane 96 Hr LC50 Pimephales promelas: 1510 – 1980 mg/L [flow-through]
13.Disposal Considerations:
Recommendation: Observe local requirements. Dispose of in accordance with local/state/federal regulations.
Empty Container Precautions: Recondition or dispose of empty container in accordance with governmental regulations.
If container is to be disposed, ensure all product residues are removed and container is empty prior to disposal.
14.Transport Information:
Not considered a dangerous good according to transport regulations unless specifically cited below:
Hazard Class Packing Group UN Number Proper Shipping Name Agency
None
15.Regulatory Information:
OSHA HAZARD COMMUNICATION STANDARD: This material is not classified as hazardous in accordance with OSHA
29 CFR 1910.1200.
SARA 311/312 Hazard Categories: None.
California Proposition 65
(Safe Drinking Water and Toxic Enforcement Act of 1986)
SDS for: 3001 Series B
Page 4 of 5
Printed: 9/20/2017 at 1:20:13PM

This product contains no substances known to the State of California to cause cancer, birth defects or other reproductive
harm, at levels which would require a warning under the statute unless otherwise listed:
Warning: This product contains chemicals known to the State of California to cause cancer and/or birth
defects or other reproductive harm:
-None
Massachusetts Right To Know List:
-None
New Jersey Right To Know List:
-None
Pennsylvania Right To Know List:
-None
SARA 302 Extremely Hazardous Substances:
-None
Chemicals subject to SARA 313 Reporting:
-None
All Components Listed Regulation Country
Canada Canada DSL Yes
US Toxic Substances Control Act Yes
16.Other Information:
Safety Data Sheet issued by Product Safety Department
This information is furnished without warranty, expressed or implied, except that it is accurate to the best knowledge of
Accella Polyurethane Systems. The data on these sheets relates only to the specific material designated herein. Accella
Polyurethane Systems assumes no legal responsibility for use or reliance upon this data. It is the user’s responsibility
to ensure that their activities comply with federal, state, or local laws.
Reviewer Revision 2 Date revised: 2017-09-20
Date Prepared: 9/20/2017
SDS for: 3001 Series B
Page 5 of 5
Printed: 9/20/2017 at 1:20:13PM