1
SAFETY DATA SHEET
PRODUCT NAME: CE 0717 A White DATE: June 17, 2015
MSDS NUMBER: CE 0717 A White SUPERSEDES MSDS: August 14, 2003
SECTION 1: MATERIAL AND MANUFACTURER IDENTIFICATION
MANUFACTURER:
Eteco, Inc.
1000 South Linwood Ave.
Santa Ana, CA 92705
Phone: 714 480 1370
TRANSPORTATION EMERGENCY CALL CHEMTREC:
800 424 9300
MEDICAL EMERGENCY INFORMATION:
800 328 8501
PRODUCT IDENTIFICATION NUMBER: CE 0717 A White
CHEMICAL FAMILY: POLYMERIC ISOCYANATE
SECTION 2: HAZARDS IDENTIFICATION
This material is classified as hazardous under OSHA Hazard Communication Standard (29 CFR 1910.1200)
Physical State and Appearance: Brown Liquid
Emergency Overview:
INHALATION OF MDI MISTS OR VAPORS MAY CAUSE RESPIRATORY IRRITATION, BREATHLESSNESS, CHEST
DISCOUMFORT AND REDUCED PULMONARY FUNCTION. OVEREXPOSURE WELL ABOVE THE PEL MAY
RESULT IN BRONCHITIS, BRONCHIAL SPASMS AND PULMONARY EDEMA. LONG-TERM EXPOSURE TO
ISOCYANATES HAS BEEN REPORTED TO CAUSE LUNG DAMAGE, INCLUDING REDUCED LUNG FUNCTION
WHICH MAY BE PERMANENT. ACUTE OR CHRONIC OVEREXPOSURE TO ISOCYANATES MAY CAUSE
SENSATION IN SOME INDIVIDUALS, RESULTING IN ALLERGIC RESPRATORY REACTIONS INCLUDING
WHEEZING, SHORTNESS OF BREATH AND DIFFICULTY BREATHING.
Skin: HAZARDOUS IN CASE OF SKIN CONTACT (IRRITANT, SENSITIZER). SKIN INFLAMMATION IS
IS CHARACTERIZED BY ITCHING, SCALING OR REDDENING.
Eyes: HAZARDOUS IN CASE OF EYE CONTACT (IRRITANT).
Inhalation: HAZARDOUS IN CASE OF INHALATION (LUNG IRRITANT, LUNG SENSITIZER).
Ingestion: SLIGHTLY HAZARDOUS IN CASE OF INGESTION.
Medical Conditions Aggravated by Overexposure: Preexisting conditions such as asthma, allergies, eczema,
bronchitis, and other lung and skin disorders may be aggravated by exposure to the product. Results from a lifetime
inhalation study in rats indicate that MDI aerosol was carcinogenic at 9 mg/m3, the highest dose tested. This is well above
the recommended TLV of 5ppb (0.05 mg/m3). Only irritation was noted at the lower concentration of 0.2 and 1 mg/m3. No
birth defects or teratogenic effects were reported in a teratology study with rats exposed to 1, 4, and 12 mg/m3 polymeric
MDI for 6 hr/day on days 6-15 of gestation. Embryotoxicity and fetotoxicity was reported at the top dose in the presence of
maternal toxicity. As a result of previous repeated overexposures or a single large dose, certain individuals will develop
isocyanate sensitization (chemical asthma), which will cause them to react to a later exposure to isocyanate at levels well
below the PEL/TVL. Those symptoms, which include chest tightness, wheezing, cough, shortness of breath, or asthmatic
attack, could be immediate of delayed up to several hours after exposure. Similar to many non-specific asthmatic
responses, there are reports that once sensitized an individual can experience these symptoms upon exposure to dust,
cold air or other irritants. This increased lung sensitivity can persist for weeks and in severe cases for several years.
Chronic overexposure to isocyanates has also been reported to cause lung damage, including a decrease in lung
function, which may be permanent. Sensitization may e either temporary of permanent. Prolonged contact can cause
reddening, swelling, rash, scaling, or blistering, in those who have developed a skin sensitization, these symptoms can
develop as a result of contact with very small amount s of liquid material, or even as a result of vapor-only exposure.
2
Aggravated Medical Conditions:
Individuals who are sensitized to isocyanates and those with preexisting lung diseases of conditions, including non-
specific bronchial hyper reactivity or asthma, must avoid all exposure to isocyanates.
GHS Label Elements:
Hazard pictograms
Signal Word: Danger
Hazard statement: Harmful if inhaled. Causes skin and eye irritation.
May Cause allergy or asthma symptoms or breathing difficulties if inhaled.
May cause an allergic skin reaction.
May cause respiratory irritation.
SECTION 3: HAZARDOUS INGREDIENTS
MATERIAL OR COMPONENT CAS
NUMBER
% BY
WEIGH
T
POLYMERIC DIPHENYLMETHANE DIISOCYANATE 9016-87-9 80-95%
PLASTISIZER 5-20%
*Occupational Exposure Limit(s) if available, are listed in section 8.
SECTION 4: FIRST AID MEASURES
Eyes: In case of eye contact, immediately flush eyes with large amounts of water for at least 15 minutes, keeping the
eyelids open. Get immediate medical attention.
Skin Contact: Remove contaminated clothing. In case of contact, immediately wash skin with soap and plenty of water.
If symptoms develop obtain medical attention. Contaminated clothing should be thoroughly cleaned. An MDI study has
demonstrated that a polyglycol-based skin cleaner or corn oil may be more effective than soap and water.
Inhalation: If excessive inhalation of vapor occurs, remove patient to fresh air. If not breathing, give artificial respiration,
preferably mouth-to-mouth. If breathing is difficult, qualified personnel may administer oxygen. Get immediate medical
attention.
Ingestion: If swallowed, dilute with water. DO NOT INDUCE VOMITING. Never give fluids or induce vomiting if the victim
is unconscious or having convulsions. Get immediate medical attention.
NOTES TO PHYSICIANS: There is no specific antidote to counteract the effects of MDI. Symptomatic and supportive
therapy as needed. Following severe exposure medical follow-up should be monitored for at least 48 hours.
Other First Aid Procedures: Medical supervision of all employees who handle or come into contact with MDI is
recommended. Pre-employment and periodic medical examinations with respiratory function test (PEV, PVC, as a
minimum are suggested). Persons with asthmatic conditions chronic bronchitis, other chronic respiratory diseased,
recurrent eczema or pulmonary sensitization should be excluded from working with MDI. Once a person is diagnosed as
having pulmonary sensitization (allergic asthma) to MDI, further exposure is not permissible.
SECTION 5: FIRE FIGHTING MEASURES
Flash Point: >93.3 C, Closed Cup.
Autoignition: >600 C.
Flammable Limits: Not available.
3
Products of Combustion: Carbon Monoxide, Carbon Dioxide, Nitrous Oxide and HCN.
Fire Hazards in Presence of Various Substances: Slightly flammable to flammable in presence of open flames, sparks
and static discharge or combustible materials.
Fire Fighting Media and Instructions: Small Fire: Use DRY chemical powder.
Large Fire: Use water spray, fog or foam. Do not use water jet.
Protective Clothing (Fire): Splash goggles. Full suit. Boots. Gloves. A self-contained breathing apparatus should be
used to avoid inhalation of the product.
Special Remarks on Fire Hazards: Reacts slowly with water to produce carbon dioxide, which may rupture closed
containers. This reaction accelerates at higher temperatures.
SECTION 6: ACCIDENTAL RELEASE MEASURES
For major spills call Chemtrec (800-424-9300)
Small Spill and Leak: Clean-up should only be performed by trained personnel. People dealing with major spillages
should wear full protective clothing including appropriate respiratory protection. Evacuate the area. Prevent further
leakage, spillage or entry into drains.
Large Spill and Leak: Contain and absorb large spillages onto an inert, non-flammable adsorbent carrier (such as earth
or sand). Shovel into open-top drums or plastic bags for further decontamination, if necessary. Wash the spillage area
with
Liquid decontaminant. Test atmosphere for MDI. Neutralize small spillages with decontaminant. Remove and properly
dispose of residues (see Section 13 for disposal considerations). Notify applicable government authorities if release is
reportable. The CERCLA RQ for 4,4-MDI is 5000 lbs (see CERCLA in Section 15).
Decontaminant: Preparation of Decontaminant Solution: Prepare a decontamination solution of 0.2-0.5% liquid detergent
and 3-8% concentrated ammonium hydroxide in water (5-10% sodium carbonate may be substituted for ammonium
hydroxide). Follow the precautions on the supplier s material safety data sheets when preparing and using solution.
Use of Decontamination Solution: Allow deactivated material to stand for at least 30 minutes before shoveling into drums.
Do not tighten the bungs. Mixing with wet earth is also effective, but slower.
SECTION 7: HANDLING AND STORAGE
Handling: Avoid personal contact with the product or reaction mixture. Use only with adequate ventilation to ensure that
the occupational exposure limit is not exceeded. The efficiency of the ventilation system must be monitored regularly
because of the possibility of blockage. Avoid breathing aerosols, mists and vapors. (See Section 8 Exposure Control for
details.)
Storage: Keep containers properly sealed and when stored indoors, in a well ventilated area. Keep contents away from
moisture. Due to reaction with water, producing CO2-gas, a hazardous build-up of pressure could result if contaminated
containers are re-sealed. Do not reseal contaminated containers. Uncontaminated containers, free of moisture, may be
resealed only after placing under a nitrogen blanket. Do not store in containers made of cooper, cooper alloys or
galvanized surfaces.
Ideal storage temperature is 16-38 C (60-100 F).
Keep stocks of decontaminant (see Section 6) readily available.
SECTION 8: EXPOSURE CONTROLS, PERSONAL PROTECTION
Preventive Measures: Conditions of use, adequacy of engineering or other control measures, and actual exposures will
dictate the need for specific protective devices at your workplace.
Engineering Controls: Use local exhaust ventilation to maintain airborne concentrations bellow the TLV. Suitable
respiratory equipment should be used in cases of insufficient ventilation or where operational procedures demand it. For
4
guidance on engineering control measures refer to publications such as the ACGIH current edition of Industrial
Ventilation, a manual of Recommended Practice .
Personal Protection
Eyes: Chemical safety goggles. If there is a potential for splashing, use a full face shield.
Body and Hands: The following protective materials are recommended: Gloves-neoprene, nitrile rubber, butyl
rubber. Thin latex disposable gloves should be avoided for repeated or long term use. Protective clothing should be
selected and used in accordance with Guidelines for the Selection of Chemical Protective Clothing published by ACGIH.
Respiratory: When the product is sprayed or heated without adequate ventilation, an approved MSHA/NIOSH
positive-pressure, supplied-air respirator may be required. Air purifying respirators equipped with organic vapor cartridges
and a HEPA (P100) particulate filter may be used under certain conditions when a cartridge change-out schedule has
been developed in accordance with the OSHA respiratory protection standard (29 C.F.R. 1910.134).
Personal Protection in Case of a Large Spills: Splash goggles. Full suit. Vapor respirator or a self-contained breathing
apparatus. Boots. Gloves. Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling
this product.
Product Name Exposure Limits
4,4-Diphenylmethane Diisocyanate ACGIH TLV 0.05 mg/m3 (8-hour, 40 hours/week) OSHA PEL Ceiling Limit 0.20 mg/m3
NIOSH REL/TWA 0.05 mg/m3 (10-hour, 40 hours/week)
NIOSH REL/CEILING 0.20 mg/m3 (10-minutes)
Exposure control/ personal protection: Medical supervision of all employees who handle or come in contact with
respiratory sensitizers is recommended. Persons with respiratory problems including asthmatic-type conditions, chronic
Bronchitis, other chronic respiratory diseases or recurrent skin eczema or skin allergies should be evaluated for their
suitability of working with this product. Once a person is diagnosed as sensitized, no further exposure to the material that
caused the sensitization should be permitted. The Occupational Exposure limits do not apply to previously sensitized
individuals.
SECTION 9: PHYSICAL AHD CHEMICAL PROPERTIES
APPEARANCE AND ODOR White Liquid
BOILING POINT ( C) >300 C
MELTING POINT ( F/ C) Not available
SPECIFIC GRAVITY ( WATER = 1) 1.23 gr/ml
BULK DENSITY 9.0 lb/gal
pH Not applicable
VAPOR PRESSURE (MM Hg.) 0.000004 mmHg @ 25 C
VAPOR DENSITY (AIR-1) 8.5
VISCOSITY 900-1300 cps @ 25 C
PERCENT (%) VOC 0%
FLASH POINTS >93.3 C (230 F) Closed Cup
SECTION 10: STABILITY AND REACTIVITY
Stability: Stable at room temperature.
Incompatibility with various Substances: Reactive with moisture.
Conditions of Instability: Avoid high temperatures. Avoid freezing.
Hazardous Decomposition Products: Carbon Monoxide, Carbon Dioxide, Nitrous Oxide and HCN.
Hazardous Polymerization: Polymerization may occur at elevated temperatures in the presence of alkalies, tertiary
amines and metal compounds.
5
SECTION 11: TOXICOLOGICAL INFORMATION
Toxicity to Animals: LD50 Rat Oral: >5000mg/kg
LD50 Rabbit Dermal: >5000 mg/kg
Inhalation: This product is a respiratory irritant and potential respiratory sensitizer. Repeated inhalation of vapor or
aerosol at levels above the occupational exposure limit could cause respiratory sensitization. Symptoms may include
irritation to the eyes, nose, throat and lungs, possibly combined with dryness of the throat, tightness of chest and difficulty
in breathing. The onset of the respiratory symptoms may be delayed for several hours after exposure. A hyper-reactive
response to even minimal concentrations of MDI may develop in sensitized persons.
Skin Contact: Moderate irritant. Repeated and/or prolonged contact may cause skin sensitization. There is limited
evidence from animal studies that skin contact may play a role in respiratory sensitization. These results emphasize the
need for protective clothing including gloves to be worn at all times when handling these chemicals or in maintenance
work.
Eye Contact: The vapor, aerosol, and liquid are irritant.
Ingestion: Ingestion may cause irritation of the gastrointestinal tract. Based on the acute oral LD50 this product is
considered practically non-toxic by ingestion.
Remarks: Short term test have shown that it is unlikely to be genotoxic. (BUTYLATEDHYDROXYTOLUENE)
Carcinogenic Effects: The ingredients of this product are not classified as carcinogenic by ACGIH or IARC, not
regulated as carcinogens by OSHA, and not listed as carcinogens by NTP.
Mutagenic Effects: There is no substantial evidence of mutagenic potential.
Reproductive Effects: No adverse reproductive effects are anticipated.
Teratogenic Effects: No birth defects were seen in two independent animal (rat) studies. Fetotoxicity was observed at
doses that were extremely toxic (including lethal) to the mother. Fetotoxicity was not observed at doses that were not
maternally toxic. The doses used in these studies were maximal respirable concentrations well in excess of the defined
limits.
Remark: A study was conducted where groups of rats were exposed for 6 hours/day, 5 days/week for a lifetime to
atmosphere of respirable polymeric MDI aerosol at concentrations of 0, 0.2, 1 or 6 mg/m3. No adverse effects were
observed at 0.2 mg/m3. At the 1mg/m3 concentration, minimal nasal and lung irritant effect were seen. Only at the top
concentration (6.0 mg/m3) was there an increased incidence of a benign tumor of the lung (adenoma). One malignant
pulmonary tumor (adenocarcinoma) was seen in the 6.0 mg/m3 group. MDI administration to rats in this study did not
change the distribution and incidence of tumors from those seen in control animals. The increased incidence of lung
tumors is associated with prolonged respiratory irritation and the concurrent accumulation of yellow material in the lung. In
the absence of prolonged exposure to high concentration leading to chronic irritation and lung damage, it is highly unlikely
that tumor formation will occur.
There are reports that excessive chronic exposure to diisocyanates may result in permanent decrease in lung function.
SECTION 12: ECOLOGICAL INFORMATION
Ecotoxicity: Polymeric MDI. LC50 (Zebra Fish) >1000 ml/l. EC50 (Daphnia magna) (24 hours) >1000 mg/l EC50 (E. Coli)
> 100ml/l.
Environmental Fate and Distribution: It is unlikely that significant environmental exposure in the air or water will arise
based on consideration of the production and use of the substance.
Persistence and Degradation: Immiscible with water, but will react with water to produce inert and non-biodegradable
solids.
SECTION 13: DISPOSAL CONSIDERATIONS
6
Waste Information: The generation of waste should be avoided or minimized wherever possible.
Disposal should be in accordance with local, state, provincial or national regulations, This material is not hazardous waste
under RCRA 40 CFR 261. Small quantities should be treated with a decontaminant solution (see Section 6). The treated
waste is not a hazardous material under RCRA 40 CFR 261. Chemical waste, even small quantities, should never be
poured down drains, sewers or waterways.
Empty containers should be decontaminated and either passed to an approved drum recycler or destroyed.
SECTION 14: TRANSPORT INFORMATION
For major spills call Chemtrec (800-424-9300).
DOT Classification: Single containers less than 5000 lbs. are not regulated. Single containers with 5000 lbs. Or more of
4,4-Methylene Diphenyl Diisocyanate are regulated as: Other Regulated Substances, Liquid, N.O.S. (Methylene Diphenyl
Diisocyanate), 9, NA3082, PGlll, RQ.
TDG Classification: Not regulated.
IMO/IMDG Classification: Not regulated.
ICAO/IATA Classification: Not regulated.
SECTION 15: REGULATORY INFORMATION
U.S. Federal Regulations
This material is classified as hazardous under OSHA Hazard Communication Standard (29 CFR 1910.1200).
HCS Classification: Class: Toxic
Class: Irritating substance.
Class: Sensitizing substance.
TSCA 8(b) inventory: All Ingredients Listed
EPCRA Section 313 (40 CFR 372)
Diisocyanate Compounds (Category Code N120) 100%
CERCLA (Comprehensive Environmental Response, Compensation and Liability Act):
This product does not contain nor is it manufactured with ozone depleting substances.
State Regulations:
Canadian Regulations: This material has been classified in accordance with the hazard criteria of the CPR (Controlled
Products Regulations) and this MSDS (Material Safety Data Sheet) contains all the information required by the CPR.
WHMIS (Canada): Class D-1A: Material causing immediate and serious toxic effects (VERY TOXIC).
Class D-2A: Material causing other toxic effects (VERY TOXIC).
Class D-2B: Material causing other toxic effects (TOXIC).
CEPA: DSL/NDSL: All Ingredients Listed.
SECTION 16: OTHER INFORMATION
CAUSES DAMAGE TO THE FOLLOWING ORGANS: LUNGS, RESPIRATORY TRACT, SKIN AND EYES. MAY BE
HARMFULL IF INHALED. MAY CAUSE RESPIRATORY TRACT, EYE AND SKIN IRRITATION. MAY CAUSE ALLERGIC
RESPIRATORY AND SKIN REACTION.
7
Hazardous Material Information System (U.S.A.) National Fire Protection Association (U.S.A.)
Health: 2 Fire Hazard: 1 Reactivity: 1 Health: 2 Fire Hazard: 1 Reactivity: 1
While the information and recommendations in this publication are to the best of our knowledge, information and belief accurate at the date
of publication, NOTHING HEREIN IS TO BE CONSTRUED AS A WARRANTY, EXPRESS OR OTHERWISE.
IN ALL CASES, IT IS THE RESPONSIBILITY OF THE USER TO DETERMINE THE APPLICATION OF SUCH INFORMATION AND
RECOMMENDATIONS AND SUITABILITY OF ANY PRODUCT FOR IRS OWN PARTICULAR PURPOSE.
THE PRODUCT MAY PRESENT HAZARD AND SHOULD BE USED WITH CAUTION, WHILE CERTAIN HAZARDS ARE DESCRIBED IN THIS
PUBLICATION, NO GUARANTEE IS MADE THAT ARE THE ONLY HAZARDS THAT EXIST.
Hazards, toxicity and behavior of the products may differ when used with other materials and are dependent upon the manufacturing
circumstances or other processes. Such hazards, toxicity and behavior should be determined by the user and made known to handlers,
processors and end users.
We disclaim liability for damage or injury incurring directly or indirectly from the use of this product.
APROVED AND AUTHORIZED BY: Enes Torlic
1
SAFETY DATA SHEET
PRODUCT NAME: CE 0717 B White Fast DATE: June 1, 2018
MSDS NUMBER: CE 0717 B White Fast SUPERSEDES MSDS: June 1, 2015
SECTION 1: MATERIAL AND MANUFACTURER IDENTIFICATION
MANUFACTURER:
Eteco, Inc.
1000 South Linwood Ave.
Santa Ana, CA 92705
Phone: 714 480 1370
TRANSPORTATION EMERGENCY CALL CHEMTREC:
800 424 9300
MEDICAL EMERGENCY INFORMATION:
800 328 8501
PRODUCTION IDENTIFICATION NUMBER: CE 0717 B White Fast
CHEMICAL FAMILY: POLYETHER POLYOL BLEND
SECTION 2: HAZARDS IDENTIFICATION
This material is classified as hazardous under OSHA Hazard Communication Standard (29 CFR 1910.1200).
Physical State: Liquid
Potential Acute Heath Effects:
Eyes Corrosive to eyes.
Skin Corrosive to skin on contact. Skin contact may produce burns.
Inhalation Inhalation of the spray mist may produce severe irritation of respiratory tract, characterized by
coughing, choking or shortness of breath.
Ingestion May cause burns to mouth, throat and stomach.
GENERAL INFORMATION: Read the entire MSDS for more thorough evaluation of the hazards.
GHS Label Elements:
Hazard pictograms
Signal Word: Warning
Hazard statement: Causes serious eye irritation
Precautionary statements: Wear eye protection, protective clothing, protective gloves. If in eyes: Rinse
cautiously with water for several minutes. Remove contact lenses, if present and
easy to do. Continue rinsing. If eye irritation persists: Get medical
advice/attention.
SECTION 3: COMPOSITION AND INFORMATION ON INGREDIENTS
MATERIAL OR COMPONENT CAS
NUMBER
% BY
WEIGHT
PROPRIETARY COMPONENT Mixture 45-80 %
GLYCOLS Mixture 0-10 %
TRIMETHYL-1,3 -PENTANEDIOL, DIISOBUTYRATE 6846-50-0 10-50%
*Occupational Exposure Limit(s), if available, are listed in Section 8.
2
SECTION 4: FIRST AID MEASURES
Eye Contact: Check for and remove any contact lenses. In case of eye contact, immediately flush eyes with
plenty of water for at least 15 minutes. Get immediate medical attention.
Skin Contact: In case of contact, immediately wash skin with soap and plenty of water for at least 15 minutes
while removing contaminated clothing and shoes. Wash clothing before reuse. Get medical attention
immediately.
Inhalation: If excessive inhalation of vapor occurs, remove to fresh air. If breathing is difficult, qualified
personnel may administer oxygen. Get medical attention immediately.
Ingestion: Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by
mouth to an unconscious person. If large quantities of this material are swallowed, call a physician
immediately. Loosen tight clothing such as a collar, tie, belt or waistband.
Notes to Physician: Symptomatic treatment and supportive therapy as indicated. Administer oxygen if
necessary.
Following severe exposure the patient should be kept under medical review for at least 48 hours as
delayed pulmonary edema may develop.
SECTION 5: FIRE FIGHTING MEASURES
Flash Point: >212 F Closed Cup
Auto Ignition Temp: Not available.
Flammable Limits: Not available.
Products of Combustion:
Thermal Decomposition products are toxic and may include oxides of carbon and nitrogen,
amines, possibly other irritating gases.
Fire Fighting Media and Instructions:
SMALL FIRE: Use DRY chemical powder.
LARGE FIRE: Use water spray, fog or foam. Do not use water jet.
Protective Clothing (Fire):
Splash goggles. Full suit. Boots. Gloves. A self-contained breathing apparatus should be used to
avoid inhalation of the product.
SECTION 6: ACCIDENTAL RELEASE MEASURES
For major spills call Chemtrec (800-424-9300)
See Safety Data Sheet section 8 Personal Protective Equipment
Small Spill and Leak Absorb with an inert material and put the material in an appropriate waste disposal container.
Large Spill and Leak Corrosive liquid. Toxic liquid.
Stop leak if without risk. Absorb with DRY earth, sand or other non-combustible material. Do not get water
inside container. Do not touch spilled material. Use water spray curtain to divert vapor drift. Use water
spray to reduce vapors. Prevent entry into sewers, basements of confined area; dike if needed. Eliminate
all ignition sources. Call for assistance on disposal. Finish cleaning by spreading water on the
contaminated surface and allow to evacuate through the sanitary system. Be careful that the product is
not present at a concentration level above TLV. Check TLV on the MSDS and with local authorities.
3
SECTION 7: HANDLING AND STORAGE
Handling Do not ingest. Do not breathe vapor or mist. Keep container closed. Use only with adequate ventilation.
Wash thoroughly after handling. Avoid contact with eyes, skin and clothing.
Storage Keep container tightly closed. Keep container in a cool, well-ventilated area.
SECTION 8: EXPOSURE CONTROLS AND PERSONAL PROTECTION
Preventive Measures Conditions of use, adequacy of engineering or other control measures, and actual exposures will
dictate the need for specific protective devices at your workplace.
Engineering Controls Use local exhaust ventilation to maintain airborne concentrations bellow the TLV. Suitable
respiratory equipment should be used in case of insufficient ventilation or where operational procedures
demand it. For guidance on engineering control measures refer to publications such as the ACGIH
current edition of Industrial Ventilation, a manual of Recommended Practice.
Personal Protection
Eyes Chemical safety goggles. If there is a potential for splashing, use a full-face shield.
Body and Hands Full chemical suit. Gloves.
Respiratory Wear appropriate respirator when ventilation is inadequate.
Personal Protection in case of a Large Spill
Splash goggles. Full suit. Vapor respirator or a self-contained breathing apparatus. Boots.
Gloves.
Suggested protective clothing might not be sufficient; consult a specialist BEFORE handling this product.
Product Name Exposure Limits
SECTION 9: PHYSICAL AHD CHEMICAL PROPERTIES
APPEARANCE AND ODOR White Slight Odor
BOILING POINT ( F/ C) Not determined
MELTING POINT ( F/ C) Not determined
SPECIFIC GRAVITY ( WATER = 1) 0.96 kg/l
BULK DENSITY 8.00 lb/gal
pH OF UNDILUTED PRODUCT Not determined
VAPOR PRESSURE (MM Hg.) Not determined
VAPOR DENSITY (AIR-1) >1
VISCOSITY 50-60 cps @ 25 C
PERCENT (%) VOC 0
SOLUBILITY IN WATER Soluble
SECTION 10: STABILITY AND REACTIVITY
Stability and Reactivity This product is stable.
Conditions of Stability Avoid moisture to protect product quality.
Incompatibility with Various Substances
Slightly reactive to reactive with oxidizing agents, alkalis.
4
Hazardous Decomposition Products
Thermal decomposition products are toxic and may include oxides of carbon and
nitrogen, amines, possibly other irritating gases.
Hazardous Polymerization Will not occur.
SECTION 11: TOXICOLOGICAL INFORMATION
No applicable data for this section.
SECTION 12I: ECOLOGICAL INFORMATION
No applicable data for this section.
SECTION 13: DISPOSAL CONSIDERATIONS
Waste Information Incinerate or landfill in a licensed facility. Do not discharge into waterways of sewer systems.
Container Disposal: Steel drums must be emptied (as defined by RCRA, Section 261.7 or state
regulations that may be more stringent) and can be sent to a licensed drum reconditoiner for reuse, a
scrap metal dealer or an approve landfill. Drums destined for scrap dealer of landfill must be punctured or
crushed to prevent reuse.
Material for disposal should be placed in appropriated sealed containers to avoid potential human and
environmental exposure. It is the responsibility of the generator to comply with all federal, state,
provincial and local laws and regulations. We recommend that you contact an appropriate waste disposal
contractor and environmental agency for relevant laws and regulations. Under the US, Resource
Conservation and Recovery Act (RCRA), it is the responsibility of the user of the product to determined at
the time of disposal, whether the product meets relevant waste classification and to assure proper
disposal.
SECTION 14: TRANSPORT INFORMATION
Transportation Emergency Number 1-800-424-9300 (CHEMTREC).
DOT Classification Non Regulated
TDG Classification Non Regulated
IMO/IMDG Classification Non Regulated
ICAO/IATA Classification Non Regulated
SECTION 15: REGULATORY INFORMATION
U.S. Federal Regulations
This material is classified as hazardous under OSHA Hazard Communication Standard (29 CFR 1910.1200).
HCS Classification
Class: Corrosive material
TSCA 8(b) inventory: All ingredients Listed.
CERCLA (Comprehensive Environmental Response, Compensation and Liability Act):
Any spill or release above the RC must be reported to the National Response Center (800-424-8802)
5
SARA 313 toxic chemical notification and release reporting: None
State Regulations California prop 65: No ingredients listed.
Canadian Regulations
This product has been classified in accordance with the hazard criteria of the CPR
(Controlled Products Regulations) and this MSDS (Material Safety Data Sheet) contains all the
information required by the CPR.
WHMIS (Canada) Class D-1B: Material causing immediate and serious toxic effects (Toxic).
Class D-2B: Material causing other toxic effects (Toxic).
CEPA DSL/NDSL Not all Ingredients Listed.
SECTION 16: OTHER INFORMATION
Causes respiratory tract, eye and skin burns.
Harmful if inhaled.
May be harmful if swallowed.
Contains material, which may cause birth defects based on animal data.
Hazardous Material Information System (U.S.A.) National Fire Protection Association (U.S.A.)
Health: 1 Health: 1
Fire Hazard: 1 Fire Hazard: 1
Reactivity: 0 Reactivity: 0
Notice to Reader
While the information and recommendations in this publication are to the best of our knowledge, information and
belief accurate at the date of publication, NOTHING HEREIN IS TO BE CONSTRUED AS A WARANTY, EXPRESS
OR OTHERWISE.
IN ALL CASES, IT IS THE RESPONSIBILITY OF THE USER TO DETERMINE THE APPLICABILITY OF SUCH
INFORMATION AND RECOMMENDATIONSAND THE SUITABILITY OF ANY PRIDUCT FOR ITS OWN PARTICULAR
PURPOSE.
THE PRODUCT MAY PRESENT HAZARDS AND SHOULD BE USED WITH CAUTION. WHILE CERTAIN HAZAEDS
ARE DESCRIBED IN THIS PUBLICATION, NO GUARANTEE IS MADE THAT THESE ARE THE ONLY HAZARDS
THAT EXIST.
Hazards, toxicity, and behavior of the products may differ when used with other materials and are dependent
upon the manufacturing circumstances or other processes. Such hazards, toxicity and behavior should be
determined by the user and made known to handlers, processors and end users.
We disclaim liability for damage or injury incurring directly or indirectly from the use of this product.
APPROVED AND AUTHORIZED BY: Enes Torlic