by | Sep 27, 2025
Acetone
Acetone (also known as dimethyl ketone and 2-propanone) is a clear, colorless, low-boiling, flammable, volatile liquid
characterized by rapid evaporation and a faintly aromatic, sweetish odor. It is readily miscible in most organic solvents
and completely miscible, in all proportions, in water. Acetone is one of the simplest aliphatic ketones, and is an excellent
solvent for a wide range of gums, resins, waxes, fats, greases, oils, dyestuffs and cellulosics. It is widely used as a
chemical intermediate in the production of methyl isobutyl ketone and other solvents, and in the production of such
important chemicals as bis-phenol-A and methyl methacrylate. It is also used in the manufacture of a wide variety of
coatings and plastics.
Typical Properties Specifications
CAS Number 67-64-1
Chemical Formula (CH
3
)
2
CO
Other/Generic Names Dimethylketone; 2-propanone; dimethylketal
Appearance Clear water white liquid
Physical State Liquid
Molecular Weight 58.08
Odor Sweetish
Density @ 20 C (68 F) 6.63 lb/US gal
Dielectric Constant @ 25 C (77 F)20.70
Specific Gravity (25 C/25 F) (77 F/77 F)Not over 0.7880
Vapor Density (Air = 1.0) 2
Vapor Pressure @ 20 C (68 F) 181.7 mmHg (3.51 psi)
Viscosity @ 15 C (59 F) 0.3371 cP
Water Solubility (miscibility) Soluble in all proportions in water
Threshold Limit (toxicity) 1000 ppm
Explosive Limits (by volume in air)Lower: 2.6%, Upper: 12.8%
Flash Point, Closed Cup -17.8 C (0 F)
Flash Point, Open Cup -9 C (15.8 F)
Autoignition Temperature 465 C (869 F)
Boiling Point (760 mm) 56.1 C (133 F)
Melting Point (Freezing Point) -94.6 C (-138 F)
Coefficient of Cubical Expansion 0.0015 ml/ml C @ 55 C
Color Colorless
CHEMICAL INTERMEDIATES
Description
Although AdvanSix Inc. believes that the information contained herein is accurate and reliable, it is presented without guarantee or responsibility of any kind and does
not constitute any representation or warranty of AdvanSix Inc., either expressed or implied. A number of factors may affect the performance of any products used in
conjunction with user s materials, such as other raw materials, application, formulation, environmental factors and manufacturing conditions among others, all of which
must be taken into account by the user in producing or using the products. The user should not assume that all necessary data for the proper evaluation of these
products are contained herein. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and
the user assumes all risks and liabilities (including, but not limited to, risks relating to results, patent infringement, regulatory compliance and health, safety and
environment) related to the use of the products and/or information contained herein.
August 2019-4, Printed in U.S.A.
2019 AdvanSix Inc. All rights reserved.
The values presented in this data sheet are typical values and are not to be interpreted as product specifications.
Contact AdvanSix
To learn more about acetone, visit
AdvanSix.com/chemicalintermediates
or call:
1-844-890-8949
(toll free, U.S./Can.)
+1-973 -526 -180 0
(international)
AdvanSix
300 Kimball Drive, Suite 101
Parsippany, NJ 07054
Physical and Chemical Properties
by | Sep 27, 2025
Material Certificate of Analysis
Date: 03/28/2024
Product: 20-80 Blend
Batch#: 21256
Specific
Gravity:
.880@75 F
Color: Clear
Fragrance: N/A
pH: N/A
Assay: Pass
Particles:
Clear and free from
suspended matter
P.O. Box 39524
4578 Brazil Street
Los Angeles, CA 90039
Tel: (323) 245-2345
(818) 242-8486
Fax (818) 242-7804
www.aglayne.com
by | Sep 27, 2025
Acetone
Acetone (also known as dimethyl ketone and 2-propanone) is a clear, colorless, low-boiling, flammable, volatile liquid
characterized by rapid evaporation and a faintly aromatic, sweetish odor. It is readily miscible in most organic solvents
and completely miscible, in all proportions, in water. Acetone is one of the simplest aliphatic ketones, and is an excellent
solvent for a wide range of gums, resins, waxes, fats, greases, oils, dyestuffs and cellulosics. It is widely used as a
chemical intermediate in the production of methyl isobutyl ketone and other solvents, and in the production of such
important chemicals as bis-phenol-A and methyl methacrylate. It is also used in the manufacture of a wide variety of
coatings and plastics.
Typical Properties Specifications
CAS Number 67-64-1
Chemical Formula (CH
3
)
2
CO
Other/Generic Names Dimethylketone; 2-propanone; dimethylketal
Appearance Clear water white liquid
Physical State Liquid
Molecular Weight 58.08
Odor Sweetish
Density @ 20 C (68 F) 6.63 lb/US gal
Dielectric Constant @ 25 C (77 F)20.70
Specific Gravity (25 C/25 F) (77 F/77 F)Not over 0.7880
Vapor Density (Air = 1.0) 2
Vapor Pressure @ 20 C (68 F) 181.7 mmHg (3.51 psi)
Viscosity @ 15 C (59 F) 0.3371 cP
Water Solubility (miscibility) Soluble in all proportions in water
Threshold Limit (toxicity) 1000 ppm
Explosive Limits (by volume in air)Lower: 2.6%, Upper: 12.8%
Flash Point, Closed Cup -17.8 C (0 F)
Flash Point, Open Cup -9 C (15.8 F)
Autoignition Temperature 465 C (869 F)
Boiling Point (760 mm) 56.1 C (133 F)
Melting Point (Freezing Point) -94.6 C (-138 F)
Coefficient of Cubical Expansion 0.0015 ml/ml C @ 55 C
Color Colorless
CHEMICAL INTERMEDIATES
Description
Although AdvanSix Inc. believes that the information contained herein is accurate and reliable, it is presented without guarantee or responsibility of any kind and does
not constitute any representation or warranty of AdvanSix Inc., either expressed or implied. A number of factors may affect the performance of any products used in
conjunction with user s materials, such as other raw materials, application, formulation, environmental factors and manufacturing conditions among others, all of which
must be taken into account by the user in producing or using the products. The user should not assume that all necessary data for the proper evaluation of these
products are contained herein. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and
the user assumes all risks and liabilities (including, but not limited to, risks relating to results, patent infringement, regulatory compliance and health, safety and
environment) related to the use of the products and/or information contained herein.
August 2019-4, Printed in U.S.A.
2019 AdvanSix Inc. All rights reserved.
The values presented in this data sheet are typical values and are not to be interpreted as product specifications.
Contact AdvanSix
To learn more about acetone, visit
AdvanSix.com/chemicalintermediates
or call:
1-844-890-8949
(toll free, U.S./Can.)
+1-973 -526 -180 0
(international)
AdvanSix
300 Kimball Drive, Suite 101
Parsippany, NJ 07054
Physical and Chemical Properties
by | Sep 27, 2025
Froth-Pak
Foam Sealant* is the complete, all-in-one self-
contained and easily portable kit for professional contractors to
quickly and efficiently fill larger gaps and penetrations sealing
out moisture, dust, allergens and pests while improving energy
efficiency, building resilience and comfort for homeowners.
The new Froth-Pak
Sealant has a GWP reduction of over
99% and contains no ozone depleting chemicals or HFCs
while maintaining the performance attributes professional
contractors expect.
Froth-Pak
Sealant s industry-leading, customizable dispensing
system helps ensure consistent flow rate, on-ratio application
and complete dispensing of product. And unlike one-component
foam, Froth-Pak
Sealant is designed to significantly reduce
curing time. It dispenses, expands and becomes tack-free in
seconds.
Froth-Pak
Sealant can be used safely in a wide range of settings,
reducing the potential for unwelcome dust, pests, moisture, mold,
mildew, allergens and rot.
TABLE 1: Sizes and Theoretical Yields for Froth-Pak
Foam Sealant
Product Theoretical Yield,
(1)
board ft
Kits
Froth-Pak
12 12 (0.03)
Froth-Pak
120 120 (0.28)
Froth-Pak
200 200 (0.46)
Froth-Pak
620 620 (1.46)
Refillable Cylinders
Froth-Pak
17 (gal) 2060 (4.85)
Froth-Pak
27 (gal) 3240 (7.65)
Froth-Pak
60 (gal) 6860 (16.2)
Froth-Pak
120 (gal) 15430 (36.4)
Froth-Pak
350 (gal) 43890 (103.6)
1
The theoretical yield has become an industry standard for identifying certain sizes of two-
component kits. Theoretical yield calculations are performed in perfect laboratory conditions,
without taking into account the loss of blowing agent or the variations in application methods
and types.
* Froth-Pak
Foam Sealant is a former product of The Dow Chemical Company.
** Actual cure time will depend on temperature, foam thickness, the specific nozzle used, etc
Ease of Use
Froth-Pak
Sealant is:
Chemically cured foam with reduced curing time
Tack free in 30 seconds and cures in minutes**
Available in refillable cylinders or disposable kits
Useful for multiple applications including roof and wall
junctions; wall and attic penetrations; basements and
crawlspaces; electrical, mechanical and plumbing
penetrations and other gaps, cracks or crevices in the
building envelope
Complete and portable two-component, quick-cure
polyurethane foam kit that fills cavities, penetrations, cracks
and expansion joints
New anti-crossover nozzle and ergonomic dispensing system
results in minimal to no overspray helps ensure consistent
flow rate, on-ratio application and complete dispensing of
product.
Contains no ozone depleting chemicals or HFCs
Blocks air infiltration and helps to meet air change per hour
(ACH) code requirements and reduce building energy costs
Reduces the potential for moisture, mold, mildew, allergens
and rot
One-hour occupant re-entry with proper ventilation after
dispensing
Faster 30 second cure time
Bonds to wood, rigid foam, masonry, metal, drywall and more
Formulation and dispensing systems are patent pending
Froth-Pak
Foam Sealant
Two-Component, Quick Cure, Professional Sealant Kit
HFC-Free, Low GWP, No Ozone Depleting Chemicals
Features and Benefits
Product Information Sheet
TABLE 2: Typical Physical Properties of Froth-Pak
Foam Sealant
These properties are typical but do not constitute specifications.
Property and Test Method Value
Flame Spread/Smoke Developed,
(2)
ASTM E84/UL 723 @ 4 wide by 2 thick 25 / 450
Nominal Density, ASTM D1622, lb/ft
3
1.75
Thermal Resistance
(3)
per inch, ASTM C518, ft
2
h F/Btu, R-value, min.
Initial
Aged LTTR measured at 2 thick
6.7
9.1
Water Vapor Permeance, ASTM E96, perm @ 1 thick 5.4
Water Absorption, ASTM D2842, % by volume 3.4
Air Permeability, ASTM E2178 is 0.0088 L/sec-m
2
@ 75Pa 0
Dimensional Stability, ASTM D2126, % volume change
158 F/100% RH @ 2 wks
-4 F/amb RH @ 2 wks
14
0.3
Compressive Strength, ASTM D1621, lb/in
2
, parallel 16.3
Flexural Strength, ASTM C203, lb/in
2
, parallel 20.1
Tensile Strength, ASTM D1623, lb/in
2
, parallel 29
Shear Strength, ASTM C273, lb/in
2
, parallel 13.8
Maximum Service Temperature, F 240
1
Tested at 2 thickness, full coverage.
2
This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
3
R means resistance to heat flow. The higher the R-value, the greater the insulating power.
Values may differ for Froth Pak 12.0 and specialty kits. Contact a DuPont representative for more information.
Properties
Review all instructions and Safety Data Sheet (SDS) before use. Please contact DuPont at 1-866-583-2583 when additional guidance
is required for writing specifications that include this product.
Testing
Applicable Standards ASTM International
C518 Standard Test Method for Steady-State Thermal
Transmission Properties by Means of the Heat Flow Meter
Apparatus
C273 Standard Test Method for Shear Properties of Sandwich
Core Materials
D1621 Standard Test Method for
Compressive Properties of Rigid Cellular Plastics
D1622 Standard Test Method for Apparent Density of Rigid
Cellular Plastics
D1623 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
D2126 Standard Test Method for Response of Rigid Cellular
Plastics to Thermal and Humid Aging
D2842 Standard Test Method for Water Absorption of
Rigid Cellular Plastics
E96 Standard Test Methods for Water Vapor Transmission
of Materials
C203 Standard Test Methods for Breaking Load and
Flexural Properties of Block-Type Thermal Insulation
Notice
Froth-Pak
Foam Sealant complies with the following codes:
CCMC 13447-L
Underwriters Laboratories, Inc. (UL) Classified, see Classification
Certificate R13655
Contact your DuPont sales representative or local authorities
for state and local building code requirements and related
acceptances.
Available Sizes
Froth-Pak
Sealant is typically sold as a complete kit that
includes pressurized A and B cylinders, Insta-Flo
a dispensing
gun/hose assembly and accessories. Froth-Pak
Sealant is also
available in refillable, returnable tanks for applications requiring
a large amount of foam, such as poultry houses. See Table 1 for
size and yield information.
Precautionary Statements
Froth-Pak
Foam will adhere to most surfaces and skin. Avoid
ALL skin contact. Wear gloves and protective clothing. Cured
foam is difficult to remove. Cured foam must be mechanically
removed or allowed to wear off in time.
WARNING: CURED FOAM IS COMBUSTIBLE AND WILL BURN
IF EXPOSED TO OPEN FLAME OR SPARKS FROM HIGH ENERGY
SOURCES. These products should not be sprayed where the
foam may come into contact with hot surfaces, such as
heaters, furnaces, fireplaces, or recessed lighting fixtures.
The foam should NOT be exposed to temperatures over
240 F (116 C).
Avoid overfilling restricted spaces. The reaction of these
chemicals causes expansion and may exert enough force to
cause an uncontrolled stream of foam, spraying the work area
and possibly the operator.
Froth-Pak
contains isocyanate, blowing agent and polyol.
Read all instructions and (M)SDS carefully before use. Wear
protective clothing and cover all skin (including long sleeves),
gloves, goggles or safety glasses, and proper respiratory
protection.
Do not breathe vapor or mist. Use only with adequate
ventilation.
Isocyanate is irritating to the eyes, skin and respiratory system,
and may cause sensitization by inhalation or skin contact.
Contents are under pressure.
Personal Protective Equipment (PPE)
Personal protective equipment (PPE) used during the handling
of Froth-Pak
foam products must at a minimum include:
Protective clothing or impermeable coveralls, such as a
Tyvek
coverall suit, including long sleeves (no skin should
be exposed)
Chemical-resistant gloves that are coated with nitrile, butyl
rubber, neoprene or PVC
Goggles or safety glasses, unless using a full-face respirator
Proper respiratory protection, see section 2.2
PPE should be worn by:
Applicator
Anyone assisting applicator
Other workers in the room within 25 ft of the applicator
Anyone entering the spray area less than one hour post
spraying with proper ventilation
If PPE is contaminated during application, properly discard and
replace immediately. Do not consume or store food or tobacco in
the work area. Make sure to wash your hands and face before
eating or smoking after application.
Safe Handling
WARNING: For Professional Use Only The Froth-Pak
cylinders contain isocyanate, blowing agent and polyols under pressure.
Read and follow product manual and the Safety Data Sheets (SDSs) (formerly MSDSs or Material Safety Data Sheets) carefully
before use. The safety precautions and personal protective equipment indicated below are designed to protect the user and allow
for the safe use and handling of the spray system. Follow all applicable federal, state, local and employer regulations..
Installation
Use Conditions
Complete operating instructions are provided with each
Froth-Pak
Foam Sealant purchase. Read all information
and cautions before application.
Froth-Pak
Foam will adhere to most surfaces and skin.
Avoid ALL skin contact. Wear gloves and protective clothing.
Check with local codes prior to use. If used in an exterior
setting, a coating must be applied for ultraviolet (UV)
protection.
Application
Avoid overfilling restricted spaces. The reaction of these
chemicals causes expansion and may exert enough force to
cause an uncontrolled stream of foam, spraying the work area
and possibly the operator.
One-hour occupant re-entry with proper ventilation after
dispensing.
Curing
Cure time will depend on temperature, foam thickness,
the specific nozzle used, etc.
Cured foam is difficult to remove. Cured foam must be
mechanically removed or allowed to wear off in time.
Equipment
Dispensing gun/hose assembly and accessories included in kit.
* See full ventilation guidelines at building.dupont.com.
For more information visit us at
frothpak.com/sealant
or call 1-833-338-7668
NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for
determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other
government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all
countries or regions. DuPont assumes no obligation or liability for the information in this document. References to DuPont or the Company mean the DuPont legal entity selling the products to Customer unless otherwise
expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. The buyer assumes all risks as to the use of the material. Buyer s exclusive remedy or any claim (including without limitations, negligence, strict
liability, or tort) shall be limited to the refund of the purchase price of the material. Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA, LLC or its affiliates, of all liability
with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers, applicators or other persons who do not purchase or utilize this product in the normal course
of their business.
DuPont Polyurethane Foam Insulation and Sealants
CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240 F. For more information, consult (M)SDS call
DuPont at 1-866-583-2583 or contact your local building inspector. In an emergency, call 1-866-583-2583. When air sealing buildings, ensure that combustion appliances, such as furnaces, water heaters, wood burning stoves,
gas stoves and gas dryers are properly vented to the outside. See website: http://www.epa.gov/iaq/homes/hip-ventilation.html. In Canada visit: http://archive.nrc-cnrc.gc.ca/eng/ibp/irc/bsi/83-house-ventilation.html.
Froth-Pak
Spray Polyurethane Foam contains isocyanate, blowing agent and polyol. Read all instructions and (M)SDS carefully before use. Wear protective clothing and cover all skin (including long sleeves), gloves, goggles
or safety glasses, and proper respiratory protection. Do not breathe vapor or mist. Use only with adequate ventilation. It is recommended that applicators and those working in the spray area wear respiratory protection.
Increased ventilation significantly reduces the potential for isocyanate exposure; however, supplied air or an approved air-purifying respirator equipped with an organic vapor sorbent and a particulate filter may still be
required to maintain exposure levels below ACGIH, OSHA, WEEL or other applicable limits. For situations where the atmospheric levels may exceed the level for which an air-purifying respirator is effective, use a
positive-pressure, air-supplying respirator (air line or self-contained breathing apparatus). Spraying large amounts of foam indoors may require the use of a positive pressure, air-supplying respirator. Contents under pressure.
Building and/or construction practices unrelated to insulation could greatly affect moisture and the potential for mold formation. No material supplier including DuPont can give assurance that mold will not develop in any
specific system.
DuPont
, the DuPont Oval Logo, and all trademarks and service marks denoted with ,
SM
or are
owned by affiliates of DuPont de Nemours, Inc. unless otherwise noted. 2021 DuPont. 43-D100068-enNA 0521 CDP
IF ATMOSPHERIC LEVELS EXCEED THE LEVEL FOR WHICH
AN AIR-PURIFYING RESPIRATOR IS EFFECTIVE A positive-
pressure, air-supplying respirator such as an air line or
self-contained breathing apparatus.
NIOSH-approved full-face or half-mask airpurifying respirator
with an organic vapor sorbent and a P100 particulate filter
For situations where the atmospheric levels may exceed
the level for which an air-purifying respirator is effective at
maintaining exposure levels below ACGIH, OSHA, WEEL or
other applicable limits, use a positive-pressure, air-supplying
respirator (air line or self-contained breathing apparatus) or
supplied air.
Change out respirator cartridges according to your employer s
change-out schedule (typically 8 hours or end of shift).
The spray foam applicator and anyone within 25 feet of the
applicator, must use approved respiratory protection.
If there is ever a doubt as to the potential limits for worker
exposure, DuPont always recommends a positive-pressure,
air-supplying respirator such as an air line or self-contained
breathing apparatus.
See the Product Manual for details
Disposal
Dispose of any residual DuPont
product, coated debris, or
solvent in accordance with applicable federal, state, and local
government regulations.
by | Sep 27, 2025
Froth-Pak
Foam Sealant* is the complete, all-in-one self-
contained and easily portable kit for professional contractors to
quickly and efficiently fill larger gaps and penetrations sealing
out moisture, dust, allergens and pests while improving energy
efficiency, building resilience and comfort for homeowners.
The new Froth-Pak
Sealant has a GWP reduction of over
99% and contains no ozone depleting chemicals or HFCs
while maintaining the performance attributes professional
contractors expect.
Froth-Pak
Sealant s industry-leading, customizable dispensing
system helps ensure consistent flow rate, on-ratio application
and complete dispensing of product. And unlike one-component
foam, Froth-Pak
Sealant is designed to significantly reduce
curing time. It dispenses, expands and becomes tack-free in
seconds.
Froth-Pak
Sealant can be used safely in a wide range of settings,
reducing the potential for unwelcome dust, pests, moisture, mold,
mildew, allergens and rot.
TABLE 1: Sizes and Theoretical Yields for Froth-Pak
Foam Sealant
Product Theoretical Yield,
(1)
board ft
Kits
Froth-Pak
12 12 (0.03)
Froth-Pak
120 120 (0.28)
Froth-Pak
200 200 (0.46)
Froth-Pak
620 620 (1.46)
Refillable Cylinders
Froth-Pak
17 (gal) 2060 (4.85)
Froth-Pak
27 (gal) 3240 (7.65)
Froth-Pak
60 (gal) 6860 (16.2)
Froth-Pak
120 (gal) 15430 (36.4)
Froth-Pak
350 (gal) 43890 (103.6)
1
The theoretical yield has become an industry standard for identifying certain sizes of two-
component kits. Theoretical yield calculations are performed in perfect laboratory conditions,
without taking into account the loss of blowing agent or the variations in application methods
and types.
* Froth-Pak
Foam Sealant is a former product of The Dow Chemical Company.
** Actual cure time will depend on temperature, foam thickness, the specific nozzle used, etc
Ease of Use
Froth-Pak
Sealant is:
Chemically cured foam with reduced curing time
Tack free in 30 seconds and cures in minutes**
Available in refillable cylinders or disposable kits
Useful for multiple applications including roof and wall
junctions; wall and attic penetrations; basements and
crawlspaces; electrical, mechanical and plumbing
penetrations and other gaps, cracks or crevices in the
building envelope
Complete and portable two-component, quick-cure
polyurethane foam kit that fills cavities, penetrations, cracks
and expansion joints
New anti-crossover nozzle and ergonomic dispensing system
results in minimal to no overspray helps ensure consistent
flow rate, on-ratio application and complete dispensing of
product.
Contains no ozone depleting chemicals or HFCs
Blocks air infiltration and helps to meet air change per hour
(ACH) code requirements and reduce building energy costs
Reduces the potential for moisture, mold, mildew, allergens
and rot
One-hour occupant re-entry with proper ventilation after
dispensing
Faster 30 second cure time
Bonds to wood, rigid foam, masonry, metal, drywall and more
Formulation and dispensing systems are patent pending
Froth-Pak
Foam Sealant
Two-Component, Quick Cure, Professional Sealant Kit
HFC-Free, Low GWP, No Ozone Depleting Chemicals
Features and Benefits
Product Information Sheet
TABLE 2: Typical Physical Properties of Froth-Pak
Foam Sealant
These properties are typical but do not constitute specifications.
Property and Test Method Value
Flame Spread/Smoke Developed,
(2)
ASTM E84/UL 723 @ 4 wide by 2 thick 25 / 450
Nominal Density, ASTM D1622, lb/ft
3
1.75
Thermal Resistance
(3)
per inch, ASTM C518, ft
2
h F/Btu, R-value, min.
Initial
Aged LTTR measured at 2 thick
6.7
9.1
Water Vapor Permeance, ASTM E96, perm @ 1 thick 5.4
Water Absorption, ASTM D2842, % by volume 3.4
Air Permeability, ASTM E2178 is 0.0088 L/sec-m
2
@ 75Pa 0
Dimensional Stability, ASTM D2126, % volume change
158 F/100% RH @ 2 wks
-4 F/amb RH @ 2 wks
14
0.3
Compressive Strength, ASTM D1621, lb/in
2
, parallel 16.3
Flexural Strength, ASTM C203, lb/in
2
, parallel 20.1
Tensile Strength, ASTM D1623, lb/in
2
, parallel 29
Shear Strength, ASTM C273, lb/in
2
, parallel 13.8
Maximum Service Temperature, F 240
1
Tested at 2 thickness, full coverage.
2
This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.
3
R means resistance to heat flow. The higher the R-value, the greater the insulating power.
Values may differ for Froth Pak 12.0 and specialty kits. Contact a DuPont representative for more information.
Properties
Review all instructions and Safety Data Sheet (SDS) before use. Please contact DuPont at 1-866-583-2583 when additional guidance
is required for writing specifications that include this product.
Testing
Applicable Standards ASTM International
C518 Standard Test Method for Steady-State Thermal
Transmission Properties by Means of the Heat Flow Meter
Apparatus
C273 Standard Test Method for Shear Properties of Sandwich
Core Materials
D1621 Standard Test Method for
Compressive Properties of Rigid Cellular Plastics
D1622 Standard Test Method for Apparent Density of Rigid
Cellular Plastics
D1623 Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
D2126 Standard Test Method for Response of Rigid Cellular
Plastics to Thermal and Humid Aging
D2842 Standard Test Method for Water Absorption of
Rigid Cellular Plastics
E96 Standard Test Methods for Water Vapor Transmission
of Materials
C203 Standard Test Methods for Breaking Load and
Flexural Properties of Block-Type Thermal Insulation
Notice
Froth-Pak
Foam Sealant complies with the following codes:
CCMC 13447-L
Underwriters Laboratories, Inc. (UL) Classified, see Classification
Certificate R13655
Contact your DuPont sales representative or local authorities
for state and local building code requirements and related
acceptances.
Available Sizes
Froth-Pak
Sealant is typically sold as a complete kit that
includes pressurized A and B cylinders, Insta-Flo
a dispensing
gun/hose assembly and accessories. Froth-Pak
Sealant is also
available in refillable, returnable tanks for applications requiring
a large amount of foam, such as poultry houses. See Table 1 for
size and yield information.
Precautionary Statements
Froth-Pak
Foam will adhere to most surfaces and skin. Avoid
ALL skin contact. Wear gloves and protective clothing. Cured
foam is difficult to remove. Cured foam must be mechanically
removed or allowed to wear off in time.
WARNING: CURED FOAM IS COMBUSTIBLE AND WILL BURN
IF EXPOSED TO OPEN FLAME OR SPARKS FROM HIGH ENERGY
SOURCES. These products should not be sprayed where the
foam may come into contact with hot surfaces, such as
heaters, furnaces, fireplaces, or recessed lighting fixtures.
The foam should NOT be exposed to temperatures over
240 F (116 C).
Avoid overfilling restricted spaces. The reaction of these
chemicals causes expansion and may exert enough force to
cause an uncontrolled stream of foam, spraying the work area
and possibly the operator.
Froth-Pak
contains isocyanate, blowing agent and polyol.
Read all instructions and (M)SDS carefully before use. Wear
protective clothing and cover all skin (including long sleeves),
gloves, goggles or safety glasses, and proper respiratory
protection.
Do not breathe vapor or mist. Use only with adequate
ventilation.
Isocyanate is irritating to the eyes, skin and respiratory system,
and may cause sensitization by inhalation or skin contact.
Contents are under pressure.
Personal Protective Equipment (PPE)
Personal protective equipment (PPE) used during the handling
of Froth-Pak
foam products must at a minimum include:
Protective clothing or impermeable coveralls, such as a
Tyvek
coverall suit, including long sleeves (no skin should
be exposed)
Chemical-resistant gloves that are coated with nitrile, butyl
rubber, neoprene or PVC
Goggles or safety glasses, unless using a full-face respirator
Proper respiratory protection, see section 2.2
PPE should be worn by:
Applicator
Anyone assisting applicator
Other workers in the room within 25 ft of the applicator
Anyone entering the spray area less than one hour post
spraying with proper ventilation
If PPE is contaminated during application, properly discard and
replace immediately. Do not consume or store food or tobacco in
the work area. Make sure to wash your hands and face before
eating or smoking after application.
Safe Handling
WARNING: For Professional Use Only The Froth-Pak
cylinders contain isocyanate, blowing agent and polyols under pressure.
Read and follow product manual and the Safety Data Sheets (SDSs) (formerly MSDSs or Material Safety Data Sheets) carefully
before use. The safety precautions and personal protective equipment indicated below are designed to protect the user and allow
for the safe use and handling of the spray system. Follow all applicable federal, state, local and employer regulations..
Installation
Use Conditions
Complete operating instructions are provided with each
Froth-Pak
Foam Sealant purchase. Read all information
and cautions before application.
Froth-Pak
Foam will adhere to most surfaces and skin.
Avoid ALL skin contact. Wear gloves and protective clothing.
Check with local codes prior to use. If used in an exterior
setting, a coating must be applied for ultraviolet (UV)
protection.
Application
Avoid overfilling restricted spaces. The reaction of these
chemicals causes expansion and may exert enough force to
cause an uncontrolled stream of foam, spraying the work area
and possibly the operator.
One-hour occupant re-entry with proper ventilation after
dispensing.
Curing
Cure time will depend on temperature, foam thickness,
the specific nozzle used, etc.
Cured foam is difficult to remove. Cured foam must be
mechanically removed or allowed to wear off in time.
Equipment
Dispensing gun/hose assembly and accessories included in kit.
* See full ventilation guidelines at building.dupont.com.
For more information visit us at
frothpak.com/sealant
or call 1-833-338-7668
NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for
determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other
government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all
countries or regions. DuPont assumes no obligation or liability for the information in this document. References to DuPont or the Company mean the DuPont legal entity selling the products to Customer unless otherwise
expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. The buyer assumes all risks as to the use of the material. Buyer s exclusive remedy or any claim (including without limitations, negligence, strict
liability, or tort) shall be limited to the refund of the purchase price of the material. Failure to strictly adhere to any recommended procedures shall release DuPont Specialty Products USA, LLC or its affiliates, of all liability
with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers, applicators or other persons who do not purchase or utilize this product in the normal course
of their business.
DuPont Polyurethane Foam Insulation and Sealants
CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240 F. For more information, consult (M)SDS call
DuPont at 1-866-583-2583 or contact your local building inspector. In an emergency, call 1-866-583-2583. When air sealing buildings, ensure that combustion appliances, such as furnaces, water heaters, wood burning stoves,
gas stoves and gas dryers are properly vented to the outside. See website: http://www.epa.gov/iaq/homes/hip-ventilation.html. In Canada visit: http://archive.nrc-cnrc.gc.ca/eng/ibp/irc/bsi/83-house-ventilation.html.
Froth-Pak
Spray Polyurethane Foam contains isocyanate, blowing agent and polyol. Read all instructions and (M)SDS carefully before use. Wear protective clothing and cover all skin (including long sleeves), gloves, goggles
or safety glasses, and proper respiratory protection. Do not breathe vapor or mist. Use only with adequate ventilation. It is recommended that applicators and those working in the spray area wear respiratory protection.
Increased ventilation significantly reduces the potential for isocyanate exposure; however, supplied air or an approved air-purifying respirator equipped with an organic vapor sorbent and a particulate filter may still be
required to maintain exposure levels below ACGIH, OSHA, WEEL or other applicable limits. For situations where the atmospheric levels may exceed the level for which an air-purifying respirator is effective, use a
positive-pressure, air-supplying respirator (air line or self-contained breathing apparatus). Spraying large amounts of foam indoors may require the use of a positive pressure, air-supplying respirator. Contents under pressure.
Building and/or construction practices unrelated to insulation could greatly affect moisture and the potential for mold formation. No material supplier including DuPont can give assurance that mold will not develop in any
specific system.
DuPont
, the DuPont Oval Logo, and all trademarks and service marks denoted with ,
SM
or are
owned by affiliates of DuPont de Nemours, Inc. unless otherwise noted. 2021 DuPont. 43-D100068-enNA 0521 CDP
IF ATMOSPHERIC LEVELS EXCEED THE LEVEL FOR WHICH
AN AIR-PURIFYING RESPIRATOR IS EFFECTIVE A positive-
pressure, air-supplying respirator such as an air line or
self-contained breathing apparatus.
NIOSH-approved full-face or half-mask airpurifying respirator
with an organic vapor sorbent and a P100 particulate filter
For situations where the atmospheric levels may exceed
the level for which an air-purifying respirator is effective at
maintaining exposure levels below ACGIH, OSHA, WEEL or
other applicable limits, use a positive-pressure, air-supplying
respirator (air line or self-contained breathing apparatus) or
supplied air.
Change out respirator cartridges according to your employer s
change-out schedule (typically 8 hours or end of shift).
The spray foam applicator and anyone within 25 feet of the
applicator, must use approved respiratory protection.
If there is ever a doubt as to the potential limits for worker
exposure, DuPont always recommends a positive-pressure,
air-supplying respirator such as an air line or self-contained
breathing apparatus.
See the Product Manual for details
Disposal
Dispose of any residual DuPont
product, coated debris, or
solvent in accordance with applicable federal, state, and local
government regulations.
by | Sep 27, 2025
Our Products are intended for sale to industrial and commercial customers. We request that Customers inspect and test our products before use and satisfy themselves as to
contents and suitability. Nothing herein shall constitute a warranty, expressed or implied, including any warranty or merchantability or fitness, nor is protection from any
law of patent to be inferred. All patent rights are reserved. The exclusive remedy for all proven claims is replacement of our materials and in no event shall we be liable for
special, incidental or consequential damages
2/22/2019 ISO 9001:2015 Registered Company
DURAKOTE GEL COATS
LOW VOC / LOW HAPS
102-010
World Class Coatings
Technology
HIGH PERFORMANCE BLACK SANDING PRIMER
____________________________________________________________________________________________
Durakote 102-010 is a Low VOC, Low HAPs, High Performance sanding primer which is designed to be used in
spray applications for open and closed molding. After de-molding, this product is easily sanded and top-coated.
The product is fully promoted and designed to use as is . This product is not recommended for applications
where the coating will see long term continuous UV radiation. This coating is color fast and light stable for short
term exterior exposure only.
PERFORMANCE BENEFITS
Excellent sand ability and process ability
Excellent recoat ability
Fast cure
Low porosity surface
Good elongation and resistance to cracking during remolding
TYPICAL LIQUID GEL COAT PROPERTIES
Gel time @77F, 2% MEKP .. 9 minutes
Gel to Peak ..15 minutes
Viscosity @ 77F, 20RPM 5000 cps
Thyrotrophic Index 6 minimum
Weight per gallon. 11.7 lbs/gal
Weight percent monomer .27.8 %
Weight percent HAPs … 27.8 %
VOC % (by weight) 34%
Solid Content % (by weight) . 66%
(Local regulations vary. Consult your local AQMD to determine actual VOC or monomer/haps % in use)
USAGE GUIDELINES
Mix this product for at least 5 minutes at low speed prior to use
MEKP levels should be kept at 2%
Do not apply gel coats below 64F
Apply using airless spray at a the lowest possible pressure
Film thickness must be between 15mils and 25mils in 2-3 passes with a short flash off time between passes
SHELF LIFE
This product is stable for six months from date of production when stored away from sunlight at no more than 77F.
Extended storage will result in some drift in gel times and viscosity. Elevated temperatures will reduce shelf life
further
by | Sep 27, 2025
by | Sep 27, 2025
by | Sep 27, 2025
SAFETY DATA SHEET
SDS Distribution: The information in this document
should be made available to all who may handle the
product.
Product ID 20-80 Blend
20-80 Blend
Page 1 of 10 www.aglayne.com
SECTION 2) HAZARDS IDENTIFICATION
Classification
Carcinogenicity – Category 1A
Eye Irritation – Category 2A
Flammable Liquids – Category 2
Germ Cell Mutagenicity – Category 1B
Skin Irritation – Category 2
Specific Target Organ Toxicity -Single Exposure (Narcotic Effects) – Category 3
Pictograms
Signal Word
Danger
Hazardous Statements – Physical
Highly flammable liquid and vapor
Hazardous Statements – Health
May cause cancer.
Causes serious eye irritation
May cause genetic defects.
Causes skin irritation
May cause drowsiness or dizziness
Precautionary Statements – General
If medical advice is needed, have product container or label at hand.
Keep out of reach of children.
SAFETY DATA SHEET
May 04, 2021
A. G. Layne, Inc.
4578 Brazil Street Los Angeles, CA, US, 90039
Manufacturer’s Name:
Revision Date:
Address:
SECTION 1) CHEMICAL PRODUCT AND MANUFACTURER’S IDENTIFICATION
Version: 1.0
Date Printed: May 04, 2021
Supersedes Date: N.A.
Product ID: 20-80 Blend
Product Name: 20-80 Blend
Emergency Phone:
Information Phone Number:
CHEMTREC US : 1-800-424-9300, INTERNATIONAL CALLS : 1-703-527-3887
323-245-2345
Fax:
Product/Recommended Uses: Industrial solvent
20-80 Blend
Page 2 of 10 www.aglayne.com
Read label before use.
Precautionary Statements – Prevention
Obtain special instructions before use.
Do not handle until all safety precautions have been read and understood.
Wear protective gloves/protective clothing/eye protection/face protection.
Wash with soap and water thoroughly after handling.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
Keep container tightly closed.
Ground/bond container and receiving equipment.
Use explosion-proof electrical/ventilating/lighting equipment.
Use only non-sparking tools.
Take action to prevent static discharges.
Avoid breathing dust/fume/gas/mist/vapors/spray.
Use only outdoors or in a well-ventilated area.
Precautionary Statements – Response
IF exposed or concerned: Get medical advice/attention.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
If eye irritation persists: Get medical advice/attention.
IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse with water or shower.
In case of fire: Use DRY chemical, alcohol- resistant foam, water spray/fog or carbon-dioxide to extinguish.
IF ON SKIN: Wash with plenty of water.
Specific treatment (see First-aid on this label).
If skin irritation occurs: Get medical advice/attention.
Take off contaminated clothing. And wash it before reuse.
IF INHALED: Remove person to fresh air and keep comfortable for breathing.
Call a POISON CENTER/doctor if you feel unwell.
Precautionary Statements – Storage
Store locked up.
Store in a well-ventilated place. Keep cool.
Store in a well-ventilated place. Store locked up.
Precautionary Statements – Disposal
Dispose of contents/container to disposal recycling center.
Waste management should be in full compliance with federal, state and local laws.
Hazards Not Otherwise Classified (HNOC)
None
SECTION 4) FIRST-AID MEASURES
CAS Chemical Name % By Weight
0000067-64-1 ACETONE 61.780% – 92.670%
0000079-20-9 METHYL ACETATE 18.220% – 27.330%
0000071-43-2 BENZENE 0 – 0.001 %
Specific chemical identity and/or exact percentage (concentration) of the composition has been withheld to protect confidentiality.
SECTION 3) COMPOSITION, INFORMATION ON INGREDIENTS
20-80 Blend
Page 3 of 10 www.aglayne.com
Inhalation
Remove source of exposure or move person to fresh air and keep comfortable for breathing. If victim is not breathing, call 911 and
administer CPR as directed.
Eliminate all ignition sources if safe to do so.
Skin Contact
Rinse/wash with lukewarm, gently flowing water (and mild soap) for 15-20 minutes or until product is removed. If skin irritation occurs or
you feel unwell: Get medical advice/attention.
Eye Contact
Remove source of exposure or move person to fresh air. Rinse eyes cautiously with lukewarm, gently flowing water for 15-20 minutes,
while holding the eyelids open. Remove contact lenses, if present and easy to do. Continue rinsing. Take care not to rinse contaminated
water into the unaffected eye or onto the face. Get immidiate medical attention.
Ingestion
Immediately call 911 POISON CENTER/doctor/.Immediately transport to the nearest medical facility for treatment.Do NOT induce
vomiting. If vomiting occurs naturally, lie on your side, in the recovery position.
Most important symptoms and effects, both acute and delayed
No data available.
Indication of any immediate medical attention and special treatment needed
No data available.
SECTION 5) FIRE-FIGHTING MEASURES
Suitable Extinguishing Media
Dry chemical, foam, carbon dioxide or fog is recommended. Water spray is recommended to cool or protect exposed materials or
structures. Carbon dioxide can displace oxygen. Use caution when applying carbon dioxide in confined spaces. Simultaneous use of
foam and water on the same surface is to be avoided as water destroys the foam. Sand or earth may be used for small fires only.
Unsuitable Extinguishing Media
No data available.
Specific Hazards in Case of Fire
No data available.
Fire-fighting Procedures
Isolate immediate hazard area and keep unauthorized personnel out. Stop spill/release if it can be done safely. Move undamaged
containers from immediate hazard area if it can be done safely. Water spray may be useful in minimizing or dispersing vapors and to
protect personnel.
Dispose of fire debris and contaminated extinguishing water in accordance with official regulations.
Special Protective Actions
Wear protective pressure self-contained breathing apparatus (SCBA) and full turnout gear.
SECTION 6) ACCIDENTAL RELEASE MEASURES
Emergency Procedure
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area).
RELEASE CAN CAUSE FIRE/EXPLOSION. LIQUIDS/VAPORS MAY IGNITE.
Do not touch or walk through spilled material.
Isolate hazard area and keep unnecessary people away. Remove all possible sources of ignition in the surrounding area. Notify
authorities if any exposure to the general public or the environment occurs or is likely to occur.
If spilled material is cleaned up using a regulated solvent, the resulting waste mixture may be regulated.
Recommended Equipment
Positive pressure, full-facepiece self-contained breathing apparatus (SCBA), or positive pressure supplied air respirator with escape
SCBA (NIOSH approved).
Personal Precautions
Avoid breathing vapor. Avoid contact with skin, eye or clothing. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in
immediate area). Use explosive proof equipment. Avoid inhalation of dust and contact with skin and eyes. Do not touch damaged
containers or spilled materials unless wearing appropriate protective clothing.
20-80 Blend
Page 4 of 10 www.aglayne.com
Environmental Precautions
Stop spill/release if it can be done safely. Prevent spilled material from entering sewers, storm drains, other unauthorized drainage
systems and natural waterways by using sand, earth, or other appropriate barriers.
Methods and Materials for Containment and Cleaning up
Sand, clay and absorbent socks can be used to contain a spill.
SECTION 7) HANDLING AND STORAGE
General
Wash hands after use.
Do not get in eyes, on skin or on clothing.
Do not breathe vapors or mists.
Use good personal hygiene practices.
Eating, drinking and smoking in work areas is prohibited.
Remove contaminated clothing and protective equipment before entering eating areas.
Eyewash stations and showers should be available in areas where this material is used and stored.
Ventilation Requirements
Use only with adequate ventilation to control air contaminants to their exposure limits. The use of local ventilation is recommended to
control emissions near the source.
Storage Room Requirements
Keep container(s) tightly closed and properly labeled. Store in cool, dry, well-ventilated areas away from heat, direct sunlight, strong
oxidizers and any incompatibilities. Store in approved containers and protect against physical damage. Keep containers securely sealed
when not in use. Indoor storage should meet OSHA standards and appropriate fire codes. Containers that have been opened must be
carefully resealed to prevent leakage. Empty container retain residue and may be dangerous.
Use non-sparking ventilation systems, approved explosion-proof equipment and intrinsically safe electrical systems in areas where this
product is used and stored.
Ground and bond containers and receiving equipment. Avoid static electricity by grounding.
Electrostatic charges may be generated during pumping. Keep away from aerosols, flammables, oxidizing agents, corrosives and from
other flammable products.
SECTION 8) EXPOSURE CONTROLS, PERSONAL PROTECTION
Eye Protection
Wear eye protection with side shields or goggles. Wear indirect-vent, impact and splash resistant goggles when working with liquids. If
additional protection is needed for entire face, use in combination with a face shield.
Skin Protection
Use of gloves approved to relevant standards made from the following materials may provide suitable chemical protection: PVC,
neoprene or nitrile rubber gloves. Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact,
chemical resistance of glove material, glove thickness, dexterity. Always seek advice from glove suppliers. Contaminated gloves should
be replaced. Use of an apron and over- boots of chemically impervious materials such as neoprene or nitrile rubber is recommended to
avoid skin sensitization. The type of protective equipment must be selected according to the concentration and amount of the dangerous
substance at the specific workplace. Launder soiled clothes or properly disposed of contaminated material, which cannot be
decontaminated.
Respiratory Protection
If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker, a respiratory protection
program that meets or is equivalent to OSHA 29 CFR 1910.134 and ANSI Z88.2 should be followed. Check with respiratory protective
equipment suppliers.
Appropriate Engineering Controls
Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold
limit value.
Chemical
Name
OSHA TWA
(ppm)
OSHA TWA
(mg/m3)
OSHA STEL
(ppm)
OSHA STEL
(mg/m3)
OSHA Tables
(Z1, Z2, Z3)
OSHA
Carcinogen
OSHA Skin
designation
NIOSH TWA
(ppm)
ACETONE 1000 2400 1 250
BENZENE 1 (a) / 25ceiling 50(a)/
10minutes.
1 1 0.1c
METHYL
ACETATE
200 610 1 200
20-80 Blend
Page 5 of 10 www.aglayne.com
Chemical
Name
NIOSH TWA
(mg/m3)
NIOSH STEL
(ppm)
NIOSH STEL
(mg/m3)
NIOSH
Carcinogen
ACGIH TWA
(ppm)
ACGIH TWA
(mg/m3)
ACGIH STEL
(ppm)
ACGIH STEL
(mg/m3)
ACETONE 590 250 500
BENZENE 1c 1 0.5 2.5
METHYL
ACETATE
610 250 760 200 250
Chemical
Name
ACGIH
Carcinogen
ACGIH
Notations
ACGIH
TLV Basis
ACETONE A4 A4; BEI URT & eye irr;
CNS impair
BENZENE A1 Skin; A1; BEI Leukemia
METHYL
ACETATE
Headache;
dizziness;
nausea; eye
dam
(degeneration
of ganglion
cells in the
retina)
(C) – Ceiling limit, A1 – Confirmed Human Carcinogen, A4 – Not Classifiable as a Human Carcinogen, BEI – Substances for which there is a
Biological Exposure Index or Indices, CNS – Central nervous system, dam – Damage, impair – Impairment, irr – Irritation, URT – Upper respiratory
tract
SECTION 9) PHYSICAL AND CHEMICAL PROPERTIES
Physical and Chemical Properties
Appearance Clear liquid
Odor Threshold N/A
Odor Description Characteristic
pH N/A
Water Solubility N/A
Flammability Flash point below 73 F/23 C
Flash Point Symbol C
Flash Point -17 ESTIMATE C
Viscosity N/A
Lower Explosion Level N/A
Upper Explosion Level N/A
Vapor Pressure N/A
Vapor Density N/A
Freezing Point N/A
Melting Point N/A
Low Boiling Point N/A
High Boiling Point N/A
Auto Ignition Temp N/A
Specific Gravity 0.82
Density 6.85 lb/gal
% VOC 0.00%
Density VOC 0.00 lb/gal
% Solids By Weight 0.00%
20-80 Blend
Page 6 of 10 www.aglayne.com
Decomposition Pt N/A
Evaporation Rate N/A
Coefficient Water/Oil N/A
VOC Composite Partial Pressure 0.00227333 mmHg
SECTION 10) STABILITY AND REACTIVITY
Stability
Stable under normal conditions of use.
Conditions to Avoid
Avoid heat, sparks, open flames and other ignition sources.
Hazardous Reactions/Polymerization
No data available.
Incompatible Materials
Strong oxidizing agents.
Hazardous Decomposition Products
Thermal decomposition may yield carbon dioxide and/or carbon monoxide.
SECTION 11) TOXICOLOGICAL INFORMATION
Likely route of exposure
Inhalation, ingestion, skin absorption
Acute toxicity
Ingestion: May be harmful or fatal if swallowed.
Based on available data, the classification criteria are not met.
Skin Corrosion/Irritation
Causes skin irritation
0000067-64-1 ACETONE
Can cause skin irritation.
Serious eye damage/irritation
Causes serious eye irritation
0000067-64-1 ACETONE
Exposure can irritate the eyes.
Germ cell mutagenicity
May cause genetic defects.
Carcinogenicity
May cause cancer.
Respiratory/Skin Sensitization
Slightly irritating to respiratory system.
Based on available data, the classification criteria are not met.
0000067-64-1 ACETONE
Can irritate the nose and throat causing coughing and wheezing.
Reproductive toxicity
Based on available data, the classification criteria are not met.
Specific Target Organ Toxicity – Repeated Exposure
Based on available data, the classification criteria are not met.
Aspiration hazard
20-80 Blend
Page 7 of 10 www.aglayne.com
Based on available data, the classification criteria are not met.
Specific Target Organ Toxicity – Single Exposure
May cause drowsiness or dizziness
0000067-64-1 ACETONE
May affect the kidneys and liver.
Likely Routes of Exposure
Inhalation, Ingestion, Skin contact, Eye contact
0000067-64-1 ACETONE
Substance can be absorbed into the body by inhalation.
Potential Health Effects – Miscellaneous
0000067-64-1 ACETONE
The following medical conditions may be aggravated by exposure: lung disease, eye disorders, skin disorders. Overexposure may cause
damage to any of the following organs/systems: blood, central nervous system, eyes, kidneys, liver, respiratory system, skin.
0000067-64-1 ACETONE
LC 50 (male rat): 30000 ppm ( 4 -hour exposure); cited as 71000 mg/m 3 ( 4 -hour exposure) ( 29 )
LC 50 (male mouse): 18600 ppm ( 4 -hour exposure); cited as 44000 mg/m 3 ( 4 -hour exposure) ( 29 )
LD 50 (oral, female rat): 5800 mg/kg ( 24 )
LD 50 (oral, mature rat): 6700 mg/kg (cited as 8.5 mL/kg) ( 31 )
LD 50 (oral, newborn rat): 1750 mg/kg (cited as 2.2 mL/kg) ( 31 )
LD 50 (oral, mouse): 3000 mg/kg ( 32 ,unconfirmed)
LD 50 (dermal, rabbit): Greater than 16000 mg/kg cited as 20 mL/kg) ( 30 )
0000079-20-9 METHYL ACETATE
LC50 (rat): 16000-32000 ppm (4-hour exposure) (9)
LD 50 (oral, rat): greater than 5000 mg/kg ( 4 )
LD 50 (oral, rabbit): 3700 mg/kg (cited as 50 millimols/kg) ( 10 )
LD 50 (skin, rabbit): greater than 5000 mg/kg ( 4 )
0000071-43-2 BENZENE
LC50 (rat): 13,700 ppm (4 hour exposure) (26); 9,980 ppm (7 hour exposure) (13,200 ppm – equivalent 4 hour exposure) (18)
LD 50 (oral, rat): 930 mg/kg ( 19 ); 5,600 mg/kg ( 2 ); 11.4 ml/kg ( 10,032 mg/kg) ( 21 )
LD 50 (oral, mouse): 4,700 mg/kg ( 11 ; unconfirmed)
LD 50 (skin, rabbit and guinea pig): Greater than 9,400 mg/kg ( 20 )
SECTION 12) ECOLOGICAL INFORMATION
Toxicity
Based on available data, the classification criteria are not met.
Mobility in Soil
0000067-64-1 ACETONE
The substance is not PBT / vPvB
The substance is not PBT / vPvB.
Bioaccumulative Potential
No data available.
Persistence and Degradability
0000067-64-1 ACETONE
91% readily biodegradable, Method: OECD Test Guideline 301B
Readily biodegradable.
Other adverse effects
No data available.
20-80 Blend
Page 8 of 10 www.aglayne.com
SECTION 13) DISPOSAL CONSIDERATIONS
Waste Disposal Method
Under RCRA it is the responsibility of the user of the product to determine at the time of disposal whether the product meets RCRA criteria
for hazardous waste. Waste management should be in full compliance with federal, state and local laws.
Empty Containers retain product residue which may exhibit hazards of material, therefore do not pressurize, cut, glaze, weld or use for
any other purposes. Return drums to reclamation centers for proper cleaning and reuse.
SECTION 14) TRANSPORT INFORMATION
U.S. DOT Information
UN1993, Flammable Liquids, N.O.S. (Acetone, Methyl Acetate) 3, PG II
Emergency Response Guide (ERG)
Emergency Response Guide 128
SECTION 15) REGULATORY INFORMATION
CAS Chemical Name % By Weight Regulation List
0000067-64-1 ACETONE 61.780% – 92.670% CERCLA,SARA312,VOC_exempt,TS
CA,RCRA,OSHA
0000079-20-9 METHYL ACETATE 18.220% – 27.330% SARA312,VOC_exempt,TSCA,OSHA
0000071-43-2 BENZENE 0 – 0.001 % SARA313,
CERCLA,SARA312,VOC,IARCCarcin
ogen,TSCA,RCRA, OSHA
Carcinogen,CA_TAC_TOX,CA_TAC_
Carcinogen,CA_Carcinogen,NEI –
National Emissions
Inventory,CA_Prop65 – California
Proposition
65,CA_Prop65_Type_Toxicity_Cance
r –
CA_Proposition65_Type_Toxicity_Ca
ncer,CA_Prop65_Type_Toxicity_Dev
elop –
CA_Proposition65_Type_Toxicity_De
velopmental,CA_Prop65_Type_Toxic
ity_Male –
CA_Proposition65_Type_Toxicity_Ma
le,OSHA
WARNING: This product can expose you to chemicals including BENZENE which is known to the State of California to cause cancer and
BENZENE which is known to the State of California to cause birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
SECTION 16) OTHER INFORMATION
General
20-80 Blend
Page 9 of 10 www.aglayne.com
A.G. Layne, Inc. urges each customer or recipient of this SDS to study it carefully and consult appropriate expertise, as necessary or
appropriate, to become aware of and understand the data contained in this SDS and any hazards associated with the product. It is the
Buyer’s/User’s responsibility to ensure that his activities comply with all Federal, State, Provincial or Local laws. The information
presented here pertains only to the product as shipped. The information contained herein is based on our current knowledge of the
underlying data and is intended to describe the product for the purpose of health, safety and environmental requirements only. NO
warranty or guarantee is expressed or implied regarding the accuracy of this data or the results to be obtained from the use of the product.
3
2
H
0
/
Health
FLAMMABILITY
Physical Hazard
Personal Protection
HMIS
( * ) – Chronic effects
Caution: HMIS ratings are based on a 0-4 rating scale, with 0 representing minimal hazards or risks, and 4 representing significant hazards or risks
Version 1.0:
Revision Date: May 04, 2021
First Edition.
DISCLAIMER
To the best of our knowledge, the information contained herein is accurate. However, neither A. G. Layne, Inc. nor any of its subsidiaries assumes any
liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole
responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we
cannot guarantee that these are the only hazards that exist. The above information pertains to this product as currently formulated, and is based on the
information available at this time. Addition of reducers or other additives to this product may substantially alter the composition and hazards of the product.
Since conditions of use are outside our control, we make no warranties, express or implied, and assume no liability in connection with any use of this
information.
20-80 Blend
Page 10 of 10 www.aglayne.com
by | Sep 27, 2025