TC-5015 A/B Page 1 of 2 Date: 05/25/2022
For more information call BJB Enterprises, Inc. (714) 734-8450 Fax (714) 734-8929
www.bjbenterprises.com

TC-5015 A/B
TRANSLUCENT SILICONE RUBBER

TC-5015 A/B is a room temperature, addition/platinum curing silicone rubber designed for making molds and parts. When
used to make molds, the TC-5015 A/B is translucent enough to see through when casting into the mold cavity. This aids in
developing void free surfaces on the casting. TC-5015 A/B is also commonly used to make ink stamp pads as well as other
types of pressure pads.

PHYSICAL PROPERTIES TEST METHOD RESULTS
Hardness, Shore A ASTM D 2240-04e1 15 5
Density (g/cc) ASTM D 792-00 1.06
Cubic Inches per Pound N/A 26.2
Color/Appearance Visual Colorless/Translucent
Tensile Strength (psi) ASTM D 412-98a(2002)e1 320
Elongation (%) ASTM D 412-98a(2002)e1 350
Tear Strength (pli) ASTM D 624-00e1 Die B 60
Shrinkage (in/in) linear ASTM D2566 @ 1 depth Nil

HANDLING PROPERTIES Part A Part B
Mix Ratio by weight 100 10
Specific Gravity @ 77 F (25 C) 1.07 0.97
Color Colorless Colorless
Viscosity (cps) @ 77 F (25 C) Brookfield 31,000 80
Mixed Viscosity (cps) @ 77 F (25 C) Brookfield 15,000
Work Time, 100g mass @ 77 F (25 C) 25 minutes
Gel Time 30 minutes
Demold Time @ 77 F (25 C) 24 hours
Properties above are typical and not for specifications.

INHIBITION:

Certain materials will cause inhibition or neutralization of the curing agent. These materials include condensation/tin cured
based silicone, lacquer and enamel coatings, polyester-based products, copper or copper containing metals, some SLA resins,
and natural rubbers like latex. Inhibition may easily be determined by brushing a small quantity of TC-5030 A/B over a
localized area of the surface to be reproduced. If the TC-5015A/B is tacky or uncured after the cure time, then you know the
mold surface is acting as an inhibitor. Molds made from wood, plaster, steel, aluminum, or plastic should not cause inhibition
if they are clean. To insure against possible problems, it is advisable to spray a barrier film over any questionable surfaces.
This is the best way of treating clays and other surfaces that cause inhibition. Contact BJB for recommended products.

SILICONE CASTING RUBBERS
Dedicated to QUALITY, SERVICE, SAFETY, and INNOVATION
An ISO-9001 Certified company

TC-5015 A/B Page 2 of 2 Date: 05/25/2022
For more information call BJB Enterprises, Inc. (714) 734-8450 Fax (714) 734-8929

NON-WARRANTY “Except for a warranty that materials substantially comply with the data presented in Manufacturer’s latest bulletin describing the product (the basis for this substantial
compliance is to be determined by the standard quality control tests generally performed by Manufacturer), all materials are sold “AS IS” and without any warranty express or implied as
to merchantability, fitness for a particular purpose, patent, trademark or copyright infringement, or as to any other matter. In no event shall Manufacturer’s liability for damages exceed
Manufacturer’s sale price of the particular quantity with respect to which damages are claimed.”

STORAGE:

Store ambient temperatures, 65-80 F (18-27 C). Unopened containers will have a shelf life of 12 months from date of
shipment when properly stored at recommended temperatures. Purge opened containers with dry nitrogen before re-sealing.

PACKAGING Part A Part B
Cubic Inches
per Kit
Quart Kits 2 lbs. 3.2 oz. 58
Gallon Kits 8 lbs. 13 oz. 231
5-Gallon Kits 40 lbs. 4 lbs. 1,153

SAFETY PRECAUTIONS:

Use in a well-ventilated area. Avoid contact with skin using protective gloves and protective clothing. Repeated or prolonged
contact on the skin may cause an allergic reaction. Eye protection is extremely important. Always use approved safety glasses
or goggles when handling this product.

IF CONTACT OCCURS:

Skin: Immediately wash with soap and water. Remove contaminated clothing and launder before reuse. It is not
recommended to remove resin from skin with solvents. Solvents only increase contact and dry skin. Seek
qualified medical attention if allergic reactions occur.
Eyes: Immediately flush with water for at least 15 minutes. Call a physician.
Ingestion: If swallowed, call a physician immediately. Remove stomach contents by gastric suction or induce vomiting only
as directed by medical personnel. Never give anything by mouth to an unconscious person.

Refer to the Material Safety Data Sheet before using this product.

Silicone Handling Guide